2016 Chinese Control and Decision Conference (CCDC) 2016
DOI: 10.1109/ccdc.2016.7531187
|View full text |Cite
|
Sign up to set email alerts
|

Safe operation improvement of an electrical power system by superconducting fault current limiters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…where E G -system EMF (electromotive force); G Z -internal resistance of the system; ( ) Z N -resistance from the short circuit point to the nearest ground wire; ( ) Z l -resistance of the line section from its beginning to the short circuit location; (3) sc ( ) I l , (2) sc ( ) I l , (1) sc ( ) I l -initial effective values of shortcircuit currents at three-phase, two-phase and one-phase short circuits, respectively.…”
Section: B the Second Methods For The Determination Of The Coordinatementioning
confidence: 99%
See 2 more Smart Citations
“…where E G -system EMF (electromotive force); G Z -internal resistance of the system; ( ) Z N -resistance from the short circuit point to the nearest ground wire; ( ) Z l -resistance of the line section from its beginning to the short circuit location; (3) sc ( ) I l , (2) sc ( ) I l , (1) sc ( ) I l -initial effective values of shortcircuit currents at three-phase, two-phase and one-phase short circuits, respectively.…”
Section: B the Second Methods For The Determination Of The Coordinatementioning
confidence: 99%
“…TO LOCATE A SHORT CIRCUIT POINT Thus, for each of the enumerated cases, knowing line parameters we can theoretically establish a relationship between the short-circuit currents and length (3) sc ( ) I l , (2) sc ( ) I l , (1) sc ( ) I l , and store the results in the memory in a tabular form.…”
Section: The Architecture Of the Network Fragment Usedmentioning
confidence: 99%
See 1 more Smart Citation
“…With the rapid development of power system, fault current levels continuously increase, and when a circuit breaker cannot interrupt a fault current, it will directly affect the safe and stable operation of the system [1]- [3]. To reduce the influence of fault currents on power system, a parallel-type circuit breaker based on a high-coupling split reactor was proposed in [4] and [5], which increased the breaking capacity.…”
Section: Introductionmentioning
confidence: 99%