Safe performance of peripheral regional anaesthesia: the significance of ultrasound guidance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
23
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 45 publications
0
23
0
2
Order By: Relevance
“…Even following the introduction of ultrasound guidance to aid regional blockade, the incidence of nerve damage seems to be unchanged . Although ultrasound gives reassurance by showing a macroscopic picture, which is useful to avoid other complications such as injections into vascular or other structures , its resolution does not allow a precise determination of the needle‐tip position with millimetric accuracy; in many cases, structures such as the nerve sheath are not clearly visible. Moreover, the alignment between the needle and ultrasound beam is often difficult and minimal unintentional displacement of the needle tip not visible with ultrasound imaging, which might occur during the injection of local anaesthetic, may result in intraneural injection.…”
Section: Introductionmentioning
confidence: 99%
“…Even following the introduction of ultrasound guidance to aid regional blockade, the incidence of nerve damage seems to be unchanged . Although ultrasound gives reassurance by showing a macroscopic picture, which is useful to avoid other complications such as injections into vascular or other structures , its resolution does not allow a precise determination of the needle‐tip position with millimetric accuracy; in many cases, structures such as the nerve sheath are not clearly visible. Moreover, the alignment between the needle and ultrasound beam is often difficult and minimal unintentional displacement of the needle tip not visible with ultrasound imaging, which might occur during the injection of local anaesthetic, may result in intraneural injection.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, minimal unintentional millimetric needle‐tip displacement during local anaesthetic injection can occur. Failure to accurately define the anatomical boundaries of nerves may contribute to unintentional intraneural injections, even under real‐time ultrasound guidance with in‐plane needle visualisation .…”
Section: Introductionmentioning
confidence: 99%
“…Vários outros modelos já foram relatados como o uso de água e gelatina/ágar 9 , Blue Phantom™ 10 e os moldes que utilizam produtos orgânicos, como modelo animal 6,7 . Por outro lado, para ser considerado ideal, o simulador de ultrassom deve possuir a ecogenicidade comparável a dos tecidos humanos 6,7,9 , estar rapidamente disponível 7 , ter baixo custo 6 , possibilidade de ser utilizado repetidamente 6,7,9,10 , promover um feedback tátil 6,7,9 , manter a agulha estática 6,7,9,10 , não deixar evidente o caminho da agulha e não causar exposição a agentes nocivos à saúde 6,7,9,[10][11][12][13] . Todas essas características puderam ser observadas no modelo proposto com adaptação de gel balístico.…”
Section: Discussionunclassified