2014
DOI: 10.5702/massspectrometry.a0031
|View full text |Cite
|
Sign up to set email alerts
|

Salt Tolerance Enhancement of Liquid Chromatography-Matrix-Assisted Laser Desorption/Ionization-Mass Spectrometry Using Matrix Additive Methylenediphosphonic Acid

Abstract: Mass spectrometry (MS) is a highly sensitive analytical technique that is o en coupled with liquid chromatography (LC). However, some bu ering salts used in LC (e.g., phosphate and tris(hydroxymethyl) aminomethane (Tris)) are incompatible with MS since they cause ion-source contamination and signal suppression. In this study, we examined salt tolerance of MALDI and applied a matrix additive methylenediphosphonic acid (MDPNA) to reduce salt-induced signal suppression. MDPNA signi cantly improved the salt tolera… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…An aliquot of the dissolved sample solution (1.0 μL) was mixed with 0.5 μL of 1% methylene-diphosphonic acid on the target plate to reduce salt-induced signal suppression 49 . After drying, the samples were mixed with 0.8 μL of 2,5-dihydroxybenzoic acid solution (5 mg/ml, Shimadzu Biotech, Kyoto).…”
Section: Lectin Affinity Chromatographymentioning
confidence: 99%
“…An aliquot of the dissolved sample solution (1.0 μL) was mixed with 0.5 μL of 1% methylene-diphosphonic acid on the target plate to reduce salt-induced signal suppression 49 . After drying, the samples were mixed with 0.8 μL of 2,5-dihydroxybenzoic acid solution (5 mg/ml, Shimadzu Biotech, Kyoto).…”
Section: Lectin Affinity Chromatographymentioning
confidence: 99%
“…One µL of sample/matrix mixture was spotted onto the MALDI target and dried in air. Methylenediphosphonic acid (MDPNA) 36) solution at a concentration of 1% (w/v) was prepared with 50% ACN with 1% TFA solution. The MDPNA solution was used for the preparation of a matrix solution with MDPNA.…”
Section: Methodsmentioning
confidence: 99%
“…Alternatively, the analyte solution (0.5 μL), the matrix solution (0.5 μL), and the MDPNA solution were mixed on a stainless-steel plate. MDPNA solution reportedly suppresses background peaks and improves sensitivity for crude, contaminated, or mixture analytes. , …”
Section: Experimental Sectionmentioning
confidence: 99%
“…MDPNA solution reportedly suppresses background peaks and improves sensitivity for crude, contaminated, or mixture analytes. 37,38 MALDI-MS. MALDI-TOFMS measurement was performed using an AXIMA Performance (Shimadzu/Kratos, UK) mass spectrometer equipped with a nitrogen UV laser (337 nm) in linear or reflectron positive-ion mode. Data was obtained using raster scanning with five shots of laser irradiation at each of 400 data points in square regions of 1000 μm × 1000 μm with a 53 μm measurement pitch (i.e., a 20 × 20 lattice) using ATHAP or CHCA.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%