2021
DOI: 10.1088/1742-6596/2071/1/012048
|View full text |Cite
|
Sign up to set email alerts
|

SAR Performance of Rectangular Microstrip Antenna for Breast Cancer Hyperthermia Treatment with Different Period of Treatment Procedure

Abstract: Cancer treatment using hyperthermia techniques recently become the interest among researchers in investigating and improving certain deficiencies of the treatment since this treatment has the potential to denaturate cancer into necrotic tissue. Hyperthermia uses high heat from 41°C to 45°C at a certain period of time. It is difficult to control the focus position distance of heat distribution on the treated tissue. Therefore, this paper presents the rectangular microstrip as hyperthermia applicator, which deli… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 8 publications
0
6
0
Order By: Relevance
“…Furthermore, in [8] [22], it presented different substrates have different effects on SAR distribution towards cancer tissues. Meanwhile, for different frequencies, it also provides differences in SAR distribution and FPD [19] .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, in [8] [22], it presented different substrates have different effects on SAR distribution towards cancer tissues. Meanwhile, for different frequencies, it also provides differences in SAR distribution and FPD [19] .…”
Section: Resultsmentioning
confidence: 99%
“…Meanwhile, the inner depth is the measurement of cancer from the tip to the last point of cancer inside the breast phantom. Figure 1 shows the measurement of the depth [19]. A 100 mm diameter breast phantom and an 18 mm diameter of malignant tissues are developed using SEMCAD X 14.8.4 software simulator.…”
Section: Breast Phantom and Cancer Developmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The frequency band used for the biomedical antenna are Medical implant communication system (MICS) at (401–406) MHz and Industrial, scientific and medical (ISM) bands at 434 MHz, 915 MHz and 2450 MHz 11 , 12 , along with 902.8–928 MHz frequency band 13 . The Federal Communications Commission (FCC) recently revealed the wireless medical telemetry service (WMTS) band for frequencies between 608–614 MHz and 1.395–1.432 GHz 14 .…”
Section: Introductionmentioning
confidence: 99%
“…Besides the above research on HTP, water bolus (WB) is another element in HTP that was proven to be able to reduce skin burn issues during the treatment [13], [14]. It is often used as a cooling material with the proposed HTP applicators [15], [16]. The implementation of WB in HTP was observed to improve the effective field size (EFS) of the EMF in the targeted tissue [17].…”
Section: Introductionmentioning
confidence: 99%