2000
DOI: 10.1364/ol.25.000350
|View full text |Cite
|
Sign up to set email alerts
|

Saturated-absorption spectroscopy with low-power difference-frequency radiation

Abstract: We report high-resolution saturated-absorption spectra recorded by use of a few microwatts of radiation generated in a single pass by difference-frequency mixing. These results were obtained without the use of buildup cavities for the nonlinear mixing or for the saturation spectroscopy. We show high-quality saturated-absorption signals for the fundamental rovibrational band of CO(2) near 4.3 mum. Convenient sources and frequency-conversion devices open new possibilities for sub-Doppler spectroscopy in the infr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
9
0

Year Published

2001
2001
2014
2014

Publication Types

Select...
5
3
2

Relationship

2
8

Authors

Journals

citations
Cited by 28 publications
(9 citation statements)
references
References 7 publications
0
9
0
Order By: Relevance
“…i(o, x, y) = a(x, y)+ b(x, y)cos[2rvx + (3) where a(x, y) and b(x, y) are the background of the intensity distribution and the amplitude of the interference fringes in the (x-y) CCD recording plane. They are supposed to be independent on the rotation angle 0 as well as slowly varying compared to the spatial frequency v along the x-axis.…”
Section: Methodsmentioning
confidence: 99%
“…i(o, x, y) = a(x, y)+ b(x, y)cos[2rvx + (3) where a(x, y) and b(x, y) are the background of the intensity distribution and the amplitude of the interference fringes in the (x-y) CCD recording plane. They are supposed to be independent on the rotation angle 0 as well as slowly varying compared to the spatial frequency v along the x-axis.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, the resolution is limited also by the absorption linewidth. However, the narrow linewidth of the DFG-based spectrometer can be of great importance when performing sub-Doppler [20] or low-pressure measurements.…”
Section: Methane (Ch 4 )mentioning
confidence: 99%
“…Only very recently, high-resolution sub-Doppler spectra have been recorded using these two nonlinear second-order processes [16][17][18] From the point of view of frequency control, difference frequency based sources are intrinsically more reliable than parametric amplifiers and oscillators. This is obviously due to the deterministic link between the difference frequency generated radiation and the two input laser frequencies.…”
Section: Introductionmentioning
confidence: 99%