2015
DOI: 10.1016/j.chroma.2015.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Schinus terebinthifolius scale-up countercurrent chromatography (Part I): High performance countercurrent chromatography fractionation of triterpene acids with off-line detection using atmospheric pressure chemical ionization mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
10
0
2

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 21 publications
2
10
0
2
Order By: Relevance
“…The solvent system selected was the two-phase solvent system: n -hexane: ethyl acetate: methanol: water 6:5:6:3 v/v/v which provided the better K values for all mayor compounds (0.5 < K < 1.3). A similar solvent system ( n -heptane–ethyl acetate–methanol–water, 6:2:6:2, v/v/v/v) was previously used for the separation of terpenoids (Vieira et al, 2015).…”
Section: Methodsmentioning
confidence: 99%
“…The solvent system selected was the two-phase solvent system: n -hexane: ethyl acetate: methanol: water 6:5:6:3 v/v/v which provided the better K values for all mayor compounds (0.5 < K < 1.3). A similar solvent system ( n -heptane–ethyl acetate–methanol–water, 6:2:6:2, v/v/v/v) was previously used for the separation of terpenoids (Vieira et al, 2015).…”
Section: Methodsmentioning
confidence: 99%
“…Off-line HPCCC-ESI-MS/MS profile. The molecular weight profiles of compounds in the HPCCC fractions were obtained via off-line injections to an ion-trap ESI mass spectrometer (HCT-Ultra ETD II, Bruker Daltonics, Bremen, Germany) in the sequence of HPCCC recovery (Vieira et al, 2015). An aliquot volume of 1.5 mL from every second HPCCC fraction (elution and extrusion steps) was pipetted to HPLC vials and directly measured, without further dilution steps.…”
Section: Hpccc Fractionationmentioning
confidence: 99%
“…In addition to UV detection and TLC analysis, off-line molecular weight MS-profiling was used for the evaluation of the HPCCC fractionation of the crude IGF extract (Vieira et al, 2015). Every observed peak corresponded to the injection of one single HPCCC fraction tube carrying the complete molecular weight information of its ionisable compounds.…”
Section: Off-line Hpccc-esi-ms/ms Profilementioning
confidence: 99%
“…CCC is a powerful tool in the phytochemical working field as it enables plant extract fractionation with existing major compounds and also isolation or fortification of minor compounds [5,6]. This characteristic is even more noticeable when semi-preparative and preparative scales are employed [7,8]. Standard CCC separation experiments do not provide the full flexibility, solely operating with a two-phase solvent system, and the isocratic elution-extrusion mode [9,10].…”
Section: Introductionmentioning
confidence: 99%