2018
DOI: 10.1007/978-981-10-9038-7_59
|View full text |Cite
|
Sign up to set email alerts
|

Selection of Entropy-Measure Parameters for Force Plate-Based Human Balance Evaluation

Abstract: The version presented here may differ from the published version or, version of record, if you wish to cite this item you are advised to consult the publisher's version. Please see the 'permanent WRAP url' above for details on accessing the published version and note that access may require a subscription.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 16 publications
(22 reference statements)
0
4
0
Order By: Relevance
“…The present study was motivated by the promising results obtained in a preliminary study, in which the issue of the adequate selection of ApEn and SampEn parameter values for COP time-series analysis was partially addressed [29]. However, the present study represents a more comprehensive investigation of this issue, as it covered a wider range of parameter values, included the ML direction in addition to the AP direction and compared the ability of ApEn and SampEn to discriminate between experimental groups to that of traditional measures of COP displacement (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The present study was motivated by the promising results obtained in a preliminary study, in which the issue of the adequate selection of ApEn and SampEn parameter values for COP time-series analysis was partially addressed [29]. However, the present study represents a more comprehensive investigation of this issue, as it covered a wider range of parameter values, included the ML direction in addition to the AP direction and compared the ability of ApEn and SampEn to discriminate between experimental groups to that of traditional measures of COP displacement (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…Fuzzy Entropy (FuzzyEn): This also uses the Heaviside function, although similarity is evaluated by a fuzzy function that computes a membership coefficient ranging from 0 to 1. Consequently, in addition to the selection of N (length over which to compute entropy), m (subsequence length), and r (tolerance in terms of the number of SDs), FuzzyEn requires a fourth parameter, n , the gradient of the boundary of the exponential function used to assess similarity [ 39 ]. FuzzyEn provides a graded similarity instead of binary similarity between parts of the time series [ 37 ].…”
Section: Methodsmentioning
confidence: 99%
“…Postural control is the result of a complex and proper interaction between physiologic systems of the human body (1)(2)(3). Two main purposes of the postural control system are the ability to maintain appropriate body orientation in Postural Control of Incontinent Females http://mjiri.iums.ac.ir Med J Islam Repub Iran.…”
Section: Introductionmentioning
confidence: 99%
“…To determine the center of pressure (COP) displacement using the force plate in quiet standing is one of the most common methods for measuring postural control (3,4). The COP is not considered as an anatomical point.…”
mentioning
confidence: 99%