2020
DOI: 10.3390/ma13112518
|View full text |Cite
|
Sign up to set email alerts
|

Self-Centering Steel–Timber Hybrid Shear Wall: Experimental Test and Parametric Analysis

Abstract: Due to timber material’s environmental benefits and satisfactory structural properties, the studies on providing solutions to the application of timber to mid-rise or even high-rise buildings have been recently increasing. Among them, the steel–timber hybrid shear wall (STHSW) is one of the promising lateral resisting systems. However, the application of the system is limited because of its unsatisfactory earthquake resilience. In this paper, a new system, self-centering (SC)-STHSW, is proposed by introducing … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 46 publications
0
2
0
Order By: Relevance
“…Unfortunately, the wall elements are not load-resisting enough for high-rise timber-based buildings, especially for those located in seismically more active areas. Thus, further study on such a steel-timber hybrid shear wall (STHSW) system in terms of better energy dissipation was carried out in [57]. In this study, a new system, i.e., self-centering (SC)-STHSW, is proposed by introducing post-tensioned (PT) technology into the previously developed STHSW system.…”
Section: Timber-steel Wall Compositesmentioning
confidence: 99%
“…Unfortunately, the wall elements are not load-resisting enough for high-rise timber-based buildings, especially for those located in seismically more active areas. Thus, further study on such a steel-timber hybrid shear wall (STHSW) system in terms of better energy dissipation was carried out in [57]. In this study, a new system, i.e., self-centering (SC)-STHSW, is proposed by introducing post-tensioned (PT) technology into the previously developed STHSW system.…”
Section: Timber-steel Wall Compositesmentioning
confidence: 99%
“…Moreover, a hybrid wall system consisting of a light-frame wood shear wall and steel frame was tested by (He et al, 2014). The aforementioned tested hybrid system was numerically investigated by (Li et al, 2014), and further developed with a post-tensioned steel frame and light frame wood shear wall by (Cui et al, 2020). Recently, a hybrid system composed of steel frames with semirigid connections and CLT shear walls was designed and analyzed by the authors (Vogiatzis et al, 2019), although the post-elastic phase was not considered in that work.…”
Section: Introductionmentioning
confidence: 99%