2021
DOI: 10.1556/1326.2021.00890
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive and validated TLC densitometry method coupled with fluorescence detection for quantitative determination of the newly co-formulated drugs, celecoxib and amlodipine besylate in tablet dosage form

Abstract: New, sensitive, rapid, cost-effective, and validated stability-indicating thin layer chromatographic (TLC) method coupled with fluorescence (FL) detection was developed for the quantitative analysis of celecoxib (CEL) and amlodipine besylate (AMLO) in their laboratory prepared binary mixture using the non-fluorescent TLC silica gel 60 plates. Ethyl acetate: diethylamine: 1-propanol (9:1:0.2, V/V) was used as a developing system. The retention factor (Rf) for each drug was 0.80 ± 0.03 and 0.44 ± 0.01 for CEL an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…For UV detection at 275 nm, TLC pre-coated silica gel aluminum plates 60 F 254 were used for simultaneous determination of IVA and MET in bulk and pharmaceutical dosage form. For fluorescence reflection mode detector at lambda excitation wavelength λex of 260 nm and K320 as cut off, the TLC silica gel plates 60 F 254 were exposed to hydrochloric acid vapors for few minutes in a closed chamber which break down the fluorescent material on TLC [ 20 ]. Consequently, the plates were converted into non-fluorescent plate (TLC silica gel 60) after air drying for an hour.…”
Section: Resultsmentioning
confidence: 99%
“…For UV detection at 275 nm, TLC pre-coated silica gel aluminum plates 60 F 254 were used for simultaneous determination of IVA and MET in bulk and pharmaceutical dosage form. For fluorescence reflection mode detector at lambda excitation wavelength λex of 260 nm and K320 as cut off, the TLC silica gel plates 60 F 254 were exposed to hydrochloric acid vapors for few minutes in a closed chamber which break down the fluorescent material on TLC [ 20 ]. Consequently, the plates were converted into non-fluorescent plate (TLC silica gel 60) after air drying for an hour.…”
Section: Resultsmentioning
confidence: 99%
“…The retention value for drugs were at recorded at 0.80 ± 0.03 and 0.44 ± 0.01 for Celecoxib and Amlodipine besylate respectively [31] . The method could estimate the binary mixture samples and forced degradation samples with required sensitivity [48] .…”
Section: Issn: 2320-4850 [90] Coden (Usa): Ajprhsmentioning
confidence: 99%
“…1), classified as a COX-2 selective NSAID, is commonly prescribed for patients with osteoarthritis and rheumatoid arthritis, being more advantageous than other NSAIDs because of its reduced gastrointestinal side effects [8]. Several analytical methods are reported in the literature for celecoxib solely or in combinations such as HPLC [9][10][11][12], spectrophotometric methods [13][14][15], TLC [16][17][18] in addition to electrochemical methods [19][20][21]. 1), an analgesic medication with dual monoaminergic reuptake inhibitory and opioid receptor agonist activities, is used for neuropathic pain, osteoarthritic pain as well as low back and rheumatoid arthritis [22].…”
Section: Introductionmentioning
confidence: 99%
“…Celecoxib (4‐[5‐(4‐methylphenyl)‐3‐(trifluoromethyl)‐1H‐pyrazol‐1‐yl] benzene sulfonamide) (Figure 1), classified as a COX‐2 selective NSAID, is commonly prescribed for patients with osteoarthritis and rheumatoid arthritis, being more advantageous than other NSAIDs because of its reduced gastrointestinal side effects [8]. Several analytical methods are reported in the literature for celecoxib solely or in combinations such as HPLC [9–12], spectrophotometric methods [13–15], TLC [16–18] in addition to electrochemical methods [19–21].…”
Section: Introductionmentioning
confidence: 99%