2014
DOI: 10.1016/j.electacta.2014.01.153
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive Voltammetric Determination of Niclosamide at a disposable pencil graphite electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
29
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 59 publications
(31 citation statements)
references
References 31 publications
2
29
0
Order By: Relevance
“…However, these techniques are limited by the low reproducibility, and there is a clear need to evaluate and propose the use of sensors that are easy to clean and that guarantee the recognized advantages of electroanalysis. Hence, the use of graphite pencil electrodes (GPE) has proven to be a useful and efficient and low cost tool for the determination of drugs in pharmaceutical formulations, without many of the drawbacks found in other methods [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…However, these techniques are limited by the low reproducibility, and there is a clear need to evaluate and propose the use of sensors that are easy to clean and that guarantee the recognized advantages of electroanalysis. Hence, the use of graphite pencil electrodes (GPE) has proven to be a useful and efficient and low cost tool for the determination of drugs in pharmaceutical formulations, without many of the drawbacks found in other methods [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…Mother milk was used for doublet aims; as it is an alternative to serum to be used without centrifugation nor sedimentation so, save time, equipment and effort, moreover this application helps for earlier detection to prevent side effects in lactating mothers, therefore, we can introduce preliminary study on the pharmacokinetics on all patients specially lactating mothers. Furthermore, PGE and GCE provide the needed advantages as simplicity, cheapness, availability, being solid and environmental friendship over the reported methods for the determination of Mep, PGE provides more advantages to be disposable, cheaper and easier to be used [16][17][18][19][20][21][22].…”
Section: Introductionmentioning
confidence: 99%
“…The advantage of PGE over the existing GCE is its high electrochemical reactivity, commercial availability, good mechanical rigidity, and low cost; the behavior of many pharmaceuticals on GCE was discussed in many of our previous researches [14][15][16]. Although PGE is relatively new type of carbon electrode, it has been successfully applied to the cathodic and anodic voltammetry by virtue of its high electrochemical reactivity, low technology, and ease of modification [17][18][19][20][21][22]. In the present work we reported the electrochemical behavior of NP⋅HCl using activated glassy carbon (GCE) and pencil graphite electrode (PGE) in Britton-Robinson buffer of pH 6.00 and 7.00 using pencil graphite electrode (PGE) and activated glassy carbon (GCE) electrode, respectively.…”
Section: Introductionmentioning
confidence: 99%