2013
DOI: 10.1007/s12647-013-0051-3
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity Enhancement of Concurrent Technique of Acoustic Impedance Measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…Baker [29] used the shear wave to evaluate the viscoelasticity of the liquid by the SRM at an early stage. In addition, Morozov, Joshi and Kumar et al [30,31] used the longitudinal wave to study the complex acoustic impedance measurement. The accuracy is improved by standardizing the measured values of the samples based on the reflectance of the air and the buffer material.…”
Section: Srm Theorymentioning
confidence: 99%
“…Baker [29] used the shear wave to evaluate the viscoelasticity of the liquid by the SRM at an early stage. In addition, Morozov, Joshi and Kumar et al [30,31] used the longitudinal wave to study the complex acoustic impedance measurement. The accuracy is improved by standardizing the measured values of the samples based on the reflectance of the air and the buffer material.…”
Section: Srm Theorymentioning
confidence: 99%
“…The tank position is measured with the help of industrial laser displacement sensor (Panasonic model: HL-G112-A-C5) with resolution of 8 lm. 3 Transducer excitation signal is generated with a programmable function generator (Agilent model: 33250A). For higher amplitude excitation E&I power amplifier is used.…”
Section: Improved Automated Radiation Force Balance Setupmentioning
confidence: 99%
“…Applications of ultrasound have been tremendously increased in last few decades in medical as well as industries [1][2][3][4][5][6]. This is particularly due to its advantages over other testing methods [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In addition to the impedance tube, which is widely used to measure the reflection coefficient of a material (usually a solid-state material), the pulse echo technique was developed to determine the acoustic impedance of a liquid by measuring the ultrasonic velocity in the liquid and its liquid density. Joshi et al [ 23 , 24 ] and Iwase et al [ 25 ] have described this technique in detail. Furthermore, ultrasound-based elastography methods were developed to determine the bulk modulus or density of hard and soft materials [ 26 ].…”
Section: Introductionmentioning
confidence: 99%