Sensitivity of Chloride Efflux vs. Transepithelial Measurements in Mixed CF and Normal Airway Epithelial Cell Populations

Abstract: Background/Aims: While the Cl -efflux assays are relatively straightforward,

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 40 publications
0
9
0
Order By: Relevance
“…aeruginosa binding to and type III secretion of exotoxins into Calu-3 airway epithelial cell monolayers occurs selectively at basolateral membranes and not at apical membranes in cells grown both as islands and on filters [ 18 , 30 ]. (iii) Activation of CFTR by forskolin and genistein in 16HBE41o- cells appears to occur similarly whether cells are grown on filters or on plastic in tissue culture well plates [ 31 ]. (iv) The release of cytosolic amino acids during physical wounding would be expected to occur similarly in polarized and nonpolarized epithelial cells.…”
Section: Discussionmentioning
confidence: 99%
“…aeruginosa binding to and type III secretion of exotoxins into Calu-3 airway epithelial cell monolayers occurs selectively at basolateral membranes and not at apical membranes in cells grown both as islands and on filters [ 18 , 30 ]. (iii) Activation of CFTR by forskolin and genistein in 16HBE41o- cells appears to occur similarly whether cells are grown on filters or on plastic in tissue culture well plates [ 31 ]. (iv) The release of cytosolic amino acids during physical wounding would be expected to occur similarly in polarized and nonpolarized epithelial cells.…”
Section: Discussionmentioning
confidence: 99%
“…Ussing chamber studies were used to characterize the electrophysiological properties of epithelial cells, such as relevant ion channel expression and transepithelial resistance. Experiments were performed using a static chamber system (World Precision Instruments, Sarasota FL) . Apical and basolateral compartments were electrically isolated and separated by the polarized epithelial layer.…”
Section: Methodsmentioning
confidence: 99%
“…Approximately 10 5 cells were plated onto each insert and grown for 9–11 days. Snapwell inserts were mounted via sliders into Easy Mount Ussing chambers (Physiologic Instruments, San Diego, Calif., USA) and short circuit current (I SC ) measurements were performed as previously described for CFBE41o- monolayers (Illek et al 2010). Briefly, a typical four-electrode voltage clamp (VCC MC6, Physiologic Instruments, San Diego, Calif., USA) was connected via Ag/AgCl electrodes (World Precision Instruments, Sarasota, Fla., USA) to the solutions through 3% Agar bridges containing 1 M KCl.…”
Section: Methodsmentioning
confidence: 99%