2012
DOI: 10.1097/bot.0b013e3182255167
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity of the Saline Load Test With and Without Methylene Blue Dye in the Diagnosis of Artificial Traumatic Knee Arthrotomies

Abstract: Diagnostic Level I. See Instructions for Authors for a complete description of levels of evidence.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
26
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(26 citation statements)
references
References 8 publications
0
26
0
Order By: Relevance
“…The observed wide range of the knee volume (40-290 ml) explains the low sensitivity and specificity of the saline load test that is used to determine a traumatic capsule defect [9][10][11][12]. This problem limits the diagnostic value of the saline load test with reported cut-off values between 60 and 194 ml [9][10][11][12].…”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…The observed wide range of the knee volume (40-290 ml) explains the low sensitivity and specificity of the saline load test that is used to determine a traumatic capsule defect [9][10][11][12]. This problem limits the diagnostic value of the saline load test with reported cut-off values between 60 and 194 ml [9][10][11][12].…”
Section: Discussionmentioning
confidence: 92%
“…This problem limits the diagnostic value of the saline load test with reported cut-off values between 60 and 194 ml [9][10][11][12].…”
Section: Discussionmentioning
confidence: 94%
“…These are CT scan,2 saline load tests (SLTs)3–6 and SLT with methylene blue 7. CT scan sensitivity and specificity for detecting TA with intra-articular air has been reported at 100% in other joints and has largely replaced the SLT 3.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, a new photosensitizer is needed for treatment of HS. Methylene blue (MB) is a phenothiazonium compound that has been approved by the US Food and Drug Authority for the treatment of methaemoglobinaemia and urinary tract infections and in some diagnostic tests …”
Section: Introductionmentioning
confidence: 99%
“…Methylene blue (MB) is a phenothiazonium compound that has been approved by the US Food and Drug Authority for the treatment of methaemoglobinaemia and urinary tract infections and in some diagnostic tests. 11,12 There are a number of drug delivery systems available to increase drug delivery to the target organ. Niosomes are non-ionic surfactant-based liposomes, and as a novel drug delivery system, can play an important role in improving the topical delivery of photosensitizers by enhancing their dermal localization and consequently optimizing efficacy of the therapeutic agents.…”
Section: Introductionmentioning