Sensorless measurement of pulsatile flow rate using a disturbance force observer in a magnetically levitated centrifugal blood pump during ventricular assistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…First, the blood flow pulsatility caused by a beating heart was not considered in the evaluation of the proposed estimation method unlike previous studies. [5][6][7][8][9]13 In this study, a steady flow could be estimated accurately using the averaged radial impeller displacement. The averaging should be performed at least for 0.15 s to remove the data noise in this experiment.…”
Section: Clinical Applications Of the Proposed Estimation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…First, the blood flow pulsatility caused by a beating heart was not considered in the evaluation of the proposed estimation method unlike previous studies. [5][6][7][8][9]13 In this study, a steady flow could be estimated accurately using the averaged radial impeller displacement. The averaging should be performed at least for 0.15 s to remove the data noise in this experiment.…”
Section: Clinical Applications Of the Proposed Estimation Methodsmentioning
confidence: 99%
“…impeller position). [10][11][12][13] Several research groups have investigated the dynamics of a magnetically levitated (maglev) impeller for application to the flow rate estimation of a blood pump with a magnetic bearing; 11,12 this has been used as a non-contact bearing in VADs such as HeartMate III (St Jude Medical, LLC) 14 and CentriMag (Thoratec Corporation) 15 to prevent blood complications in VAD applications.…”
Section: Introductionmentioning
confidence: 99%
“…The MagLev RBP was connected to a mock circulatory loop consisting of a pulsatile pump, an aorta simulator, a left atrium simulator, and a fluid resistance. The details of the mock circulatory loop are described in reference . The same ultrasonic flow meter and pressure transducers described above were used for the measurements.…”
Section: Methodsmentioning
confidence: 99%
“…External devices such as VAD have also a great potential to be used as model-based sensors, enabling for example, the measurement of the blood flow rate, based on electric current in the magnetic bearing that supports the rotor of the VAD [173].…”
Section: Recommendationsmentioning
confidence: 99%