Purpose: Assessment of drug substance and excipients compatibility is an important issue during pre-formulation studies as well as the quality control of pharmaceutical dosage forms. In this study, potential incompatibility between methyldopa and reducing excipients was evaluated using physicochemical methods.Methods: Dextrose and lactose (anhydrous & monohydrate) were selected as reducing carbohydrates. The initial incompatibility was studied with DSC and FTIR on binary mixtures with 1:1 mass ratio. Results were confirmed using HPLC studies coupled with mass spectrometry.Results: The DSC curves indicated the elimination of the melting endotherm of methyldopa in the binary mixtures. A new peak at 1719 cm-1 was observed in the FTIR spectra that can be attributed to the loss of type one amine functionality. The m/z of the proposed compound was observed in the mass spectra.Conclusion: The potential incompatibility of Methyldopa with reducing carbohydrates was established using physicochemical methods.