1998
DOI: 10.1007/bf02467681
|View full text |Cite
|
Sign up to set email alerts
|

Separation of fluorescein dyes by capillary electrophoresis using β-cyclodextrin

Abstract: SummaryA capillary electrophoresis method for the separation and determination of five synthetic dyes used in pharmaceutical preparations, cosmetics and as food additives is described. The dyes, fluorescein, dichlorofluorescein, Rose Bengal, erythrosine and eosine are well separated in less than 12 min using an electrolyte of 50 mM phosphate buffer (pH 7.5), 10 mM [~-cyclodextrin and 5 % (v/v) methanol. A linear relationship between concentration and peak area for each dye was obtained in the concentration ran… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
2
0

Year Published

2000
2000
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 11 publications
2
2
0
Order By: Relevance
“…With the above calculations, one can derive the mean electrophoretic mobility of fluorescein for the performed experiments applying eq , which results in µ f = (1.42 ± 0.1) × 10 −4 cm 2 (V s) −1 . This value is lower than in previous CE related publications; however, the values correspond to values obtained, e.g., by Fonslow et al with a μ-FFE device . In terms of voltage efficiency, as defined by the ratio of the utilized voltage for separation and the total applied voltage, the system suffers from the potential loss across the electrode regions.…”
Section: Resultssupporting
confidence: 47%
“…With the above calculations, one can derive the mean electrophoretic mobility of fluorescein for the performed experiments applying eq , which results in µ f = (1.42 ± 0.1) × 10 −4 cm 2 (V s) −1 . This value is lower than in previous CE related publications; however, the values correspond to values obtained, e.g., by Fonslow et al with a μ-FFE device . In terms of voltage efficiency, as defined by the ratio of the utilized voltage for separation and the total applied voltage, the system suffers from the potential loss across the electrode regions.…”
Section: Resultssupporting
confidence: 47%
“…5.1 (16c;16f)). This value is lower than in previous CE related publications [104], however, correspond to values obtained e.g. by Fonslow et al with a µ-FFE device [35].…”
Section: Quantitative Bubble Influencesupporting
confidence: 72%
“…developed an HPLC coupled with fluorescence detection method to rapidly, simply, and sensitively determine rhodamine B in chili‐containing products. However, CE is superior to these methods, and it requires significantly less injection volume (nanoscale) compared to HPLC does (microscale) and saves organic reagents .…”
Section: Resultsmentioning
confidence: 99%