2013
DOI: 10.1016/j.talanta.2013.05.051
|View full text |Cite
|
Sign up to set email alerts
|

Sequential injection system for simultaneous determination of sucrose and phosphate in cola drinks using paired emitter-detector diode sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
14
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 29 publications
(14 citation statements)
references
References 34 publications
0
14
0
Order By: Relevance
“…Sucrose (equivalent to • Bx) and orthophosphate was carried out using a benchtop spectrophotometer. Sucrose was detected based on the schlieren effect at the interface between sample and pure water plugs [19][20][21][22][23][24], as our reported for analysis of sucrose in beverages [19][20][21]. Orthophosphate analysis was achieved by the molybdenum blue method, instead of turbidimetry [19], to avoid the adsorption of the in-line precipitates on the inner wall of PTFE tubing.…”
Section: Introductionmentioning
confidence: 99%
“…Sucrose (equivalent to • Bx) and orthophosphate was carried out using a benchtop spectrophotometer. Sucrose was detected based on the schlieren effect at the interface between sample and pure water plugs [19][20][21][22][23][24], as our reported for analysis of sucrose in beverages [19][20][21]. Orthophosphate analysis was achieved by the molybdenum blue method, instead of turbidimetry [19], to avoid the adsorption of the in-line precipitates on the inner wall of PTFE tubing.…”
Section: Introductionmentioning
confidence: 99%
“…25,26 The PEDD has been employed in the analysis of physiological samples, [27][28][29][30][31][32][33][34][35][36][37][38][39][40] drink and food samples [41][42][43][44] and environmental samples. 45 There are also reports of dual analysis employing PEDDs, for example, multicommutated flow (MCFA) system for the determination of activity of acid phosphate and alkaline phosphatase, 46 sequential injection (SI) system for quantitative measurement of sucrose and phosphate, 47 MCFA system for determination of phosphate and calcium, 48 MCFA system for total protein and creatinine analysis 49 and MCFA system for investigation of iron-transferrin and apotransferrin speciation in human serum. 50 Recently, Kalinowski and Koronkiewicz described the use of a double-PEDD to measure absorbance in the double-beam photometric mode, where one of the PEDDs was employed for reaction detection and the other employed for reference detection.…”
Section: Introductionmentioning
confidence: 99%
“…Pairing two properly selected LEDs, one for emission and one for detection (paired emitter detector diode (PEDD)), enhances selectivity and enables us to prepare a detector dedicated for some specific determinations, where optical filters can be eliminated. Such systems can be employed for analytical purposes, for example, for phosphate determination (Bui and Hauser 2013 ; Fiedoruk et al 2014 ; O’Toole et al 2007 ; Saetear et al 2013 ; Shin et al 2016 ).…”
Section: Introductionmentioning
confidence: 99%