1972
DOI: 10.1111/j.1151-2916.1972.tb11340.x
|View full text |Cite
|
Sign up to set email alerts
|

Settling of Particles in Fresh Cement Pastes

Abstract: Critical comparison of the results of previous experimental studies of the settling of cement pastes at different watercement ratios exposed inconsistencies in published theories. Development of a y-ray densitometer made it possible to measure the change in density of columns of freshly prepared cement paste with time of settIing in containers of clear poly(methylmethacry1ate) plastic. Paste density increased at all levels in the columns; the changes were greater at the greater depths, suggesting that the sett… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1972
1972
2020
2020

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(7 citation statements)
references
References 4 publications
0
7
0
Order By: Relevance
“…Alternative approaches include those analysing the transmission-attenuation response of laser light in sample based devices such as the Lumizier (from Lum GmbH) and Turbiscan (Formulation, SA) [9][10][11]; however, these ex situ systems are only suitable for small sample analysis of slowly evolving suspensions. In situ devises include light based transmission/backscatter or fluorescence devices [12][13][14][15][16][17][18], CCD video analysis [19][20][21][22][23], gamma ray [24,25] or x-ray CATSCAN [26], and also tomographic techniques which measure electrical resistance within suspensions [27,28]. However, a number of these techniques suffer from common limitations to their use, such complicated set-ups that encompass specific vessel requirements (and hence are not suitable for deployment industrially) while many are highly intrusive, or complex and expensive in application [29].…”
Section: Introductionmentioning
confidence: 99%
“…Alternative approaches include those analysing the transmission-attenuation response of laser light in sample based devices such as the Lumizier (from Lum GmbH) and Turbiscan (Formulation, SA) [9][10][11]; however, these ex situ systems are only suitable for small sample analysis of slowly evolving suspensions. In situ devises include light based transmission/backscatter or fluorescence devices [12][13][14][15][16][17][18], CCD video analysis [19][20][21][22][23], gamma ray [24,25] or x-ray CATSCAN [26], and also tomographic techniques which measure electrical resistance within suspensions [27,28]. However, a number of these techniques suffer from common limitations to their use, such complicated set-ups that encompass specific vessel requirements (and hence are not suitable for deployment industrially) while many are highly intrusive, or complex and expensive in application [29].…”
Section: Introductionmentioning
confidence: 99%
“…The hardened CSD samples were removed from the mold and the open-end of the mold was marked on the samples. This was to observe the influence of slurry sedimentation on the results (Wheeler and Chaterji, 1972). The CSD samples were left to set at room temperature for 20 days.…”
Section: Preparation Of Csd Samplesmentioning
confidence: 99%
“…Taking this into account, sedimentation induced collisions were not considered. Given the typical settling velocities observed in fresh cement pastes [38,39], the small gap width in this experimental geometry and the time frame the model aims to capture, significant amounts of sedimentation should not occur. Thus, the collision frequency term in Equation (17) adopts the form of the widely known expression for orthokinetic aggregation under laminar shear flow [35,40]:…”
Section: Modelmentioning
confidence: 99%