2014
DOI: 10.1109/mias.2013.2288408
|View full text |Cite
|
Sign up to set email alerts
|

Sharing Transient Loads : Causes of Unequal Transient Load Sharing in Islanded Microgrid Operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
56
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
3
3
2

Relationship

0
8

Authors

Journals

citations
Cited by 115 publications
(58 citation statements)
references
References 19 publications
1
56
0
1
Order By: Relevance
“…Single-loop control is also used, most notably by CERTS [10,11], which at present is arguably the most advanced microgrid development program in the United States. This paper is follow-on research to [6], which used single-loop control, and therefore both single-loop and multi-loop controls are investigated in this paper. One favorable property of single-loop control for microgrids is the reduced sensitivity to impedance-related stability, as will be observed in the small-signal analysis of Section IV.B.…”
Section: A Single-loop and Multi-loop Inverter Controlmentioning
confidence: 99%
See 2 more Smart Citations
“…Single-loop control is also used, most notably by CERTS [10,11], which at present is arguably the most advanced microgrid development program in the United States. This paper is follow-on research to [6], which used single-loop control, and therefore both single-loop and multi-loop controls are investigated in this paper. One favorable property of single-loop control for microgrids is the reduced sensitivity to impedance-related stability, as will be observed in the small-signal analysis of Section IV.B.…”
Section: A Single-loop and Multi-loop Inverter Controlmentioning
confidence: 99%
“…This is because of the inverter and generator's different frequency regulation characteristics [6]. The control diagram for a synchronous generator operating with voltage and frequency droop is shown in Fig.…”
Section: A Transient Power Sharing Characteristics Between Invertersmentioning
confidence: 99%
See 1 more Smart Citation
“…The converter output is monitored to achieve the targets only through receiving feedback from current output disregarding the voltage range. In order to achieve more accurate and practical results, it is suggested to measure the output voltage and current of converters [15,16]. Given the optimal allocation of power between DG units, the controlling effect on the circulating currents among resources is necessary to reduce power losses.…”
Section: Introductionmentioning
confidence: 99%
“…An investigation was carried out in [8] to fmd the cause for poor transient load sharing in an islanded microgrid. In [9] and [10], a modified droop control technique and virtual impedance was proposed to limit the inverter' s current during overloads.…”
mentioning