2015
DOI: 10.1088/0963-0252/24/1/015032
|View full text |Cite
|
Sign up to set email alerts
|

Sheath expansion of two-dimensional grid electrodes subjected to short pulses of negative high-voltage

Abstract: Sheath expansion was investigated for two-dimensional (2D) grid electrodes which consist of a periodic array of cylindrical electrodes when short pulses of negative high-voltage were applied to the electrodes immersed in plasmas. In the sheath expansion model, a geometric function which describes the electrode system is crucial to numerically calculate the temporal evolution of a sheath boundary. In this paper, the 2D geometric function of grid electrodes was obtained by using XOOPIC (particle-in-cell) simulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
5
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(6 citation statements)
references
References 31 publications
1
5
0
Order By: Relevance
“…When particles collided with the boundary electrodes, they were lost. These simulation conditions showed good agreement with the experimental results of transient sheath expansion of grid electrodes in our previous work [20]. Since transient sheath expansions are determined by ion distributions (Child-Langmuir currents) in expanding sheaths [1,2], the simulation conditions described above were a reasonable choice for properly simulating ion distributions in expanding collisionless sheaths.…”
Section: Simulation Setupsupporting
confidence: 78%
See 4 more Smart Citations
“…When particles collided with the boundary electrodes, they were lost. These simulation conditions showed good agreement with the experimental results of transient sheath expansion of grid electrodes in our previous work [20]. Since transient sheath expansions are determined by ion distributions (Child-Langmuir currents) in expanding sheaths [1,2], the simulation conditions described above were a reasonable choice for properly simulating ion distributions in expanding collisionless sheaths.…”
Section: Simulation Setupsupporting
confidence: 78%
“…In many cases, the ion distributions near the surface of electrodes were mainly studied for industrial applications such as the modification of the surface properties of materials using energetic ions. However, for grid electrodes, which are frequently used in basic plasma research [17] and industrial plasma applications [14,15,18,19], ion distributions in the entire region of an expanding sheath are important for investigating the characteristics of sheath expansion [20] and pseudo wave generation [17].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations