2018
DOI: 10.1063/1.5024734
|View full text |Cite
|
Sign up to set email alerts
|

Shielding and diagnostics of laser-induced air plasmas generated in collinear double pulse configuration

Abstract: Plasma shielding in collinear double-pulse laser-induced breakdown spectroscopy was characterized in terms of its time-resolved absorptivity, photographic images, and emission spectra. In experiments performed with the double pulse beam configuration, one to generate plasma and another a probe beam, the transmission of the probe beam was measured at various inter-pulse delay times up to 1500 ns as the plasma opacity evolves rapidly with time. Photographic images obtained at the same time delay indicate that th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(1 citation statement)
references
References 30 publications
0
1
0
Order By: Relevance
“…For example, Wang et al compared femtosecond DP-LIBS spectra at different pulse intervals [14] and found that the Fe I 427.18 nm line can be enhanced up to 3 times, which can be attributed to the plasma re-heating effects of the second laser pulse. Li et al utilized reheating DP-LIBS to analyze trace copper elements in micro-alloyed steel [15] and found that the enhancement degree of the spectral line is related to its excitation level, which indicates that the reheating laser facilitates a larger and hotter plasma. In DP-LIBS-induced air plasma shielding and diagnostics, Zhang et al found that the plasma temperature is slightly higher than that of single-pulse LIBS [16].…”
Section: Introductionmentioning
confidence: 99%
“…For example, Wang et al compared femtosecond DP-LIBS spectra at different pulse intervals [14] and found that the Fe I 427.18 nm line can be enhanced up to 3 times, which can be attributed to the plasma re-heating effects of the second laser pulse. Li et al utilized reheating DP-LIBS to analyze trace copper elements in micro-alloyed steel [15] and found that the enhancement degree of the spectral line is related to its excitation level, which indicates that the reheating laser facilitates a larger and hotter plasma. In DP-LIBS-induced air plasma shielding and diagnostics, Zhang et al found that the plasma temperature is slightly higher than that of single-pulse LIBS [16].…”
Section: Introductionmentioning
confidence: 99%