2013
DOI: 10.1109/tps.2013.2277981
|View full text |Cite
|
Sign up to set email alerts
|

Short-Pulse Marx Generator for High-Power Microwave Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(6 citation statements)
references
References 3 publications
0
6
0
Order By: Relevance
“…When C 1 is 41.6μF, the corresponding curve has larger (i 1 ) max than another one. Equation (8) indicates that C 1 has no effect on (di 1 /dt) max . However (di 1 /dt) max for two values of C 1 still has a tiny deviation.…”
Section: Electrical Parametersmentioning
confidence: 99%
See 2 more Smart Citations
“…When C 1 is 41.6μF, the corresponding curve has larger (i 1 ) max than another one. Equation (8) indicates that C 1 has no effect on (di 1 /dt) max . However (di 1 /dt) max for two values of C 1 still has a tiny deviation.…”
Section: Electrical Parametersmentioning
confidence: 99%
“…The circuit resistance, the turn-on resistance of thyristor and other factors are not considered when equation (8) is deduced. When i 1 changes, these ignored factors may have some effects on the calculation result of equation (8). Secondly, k eff is supposed to be unchanged as the prototype is constructed.…”
Section: Electrical Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…One is the Tesla transformer, for example, the Sinus-type ultra-wideband system developed by the Institute of High Current Electronics (HCEI) [9][10][11][12], and RADAN series developed at the Institute of Electrophysics [13]. e other is to use the Marx generator to generate high-voltage pulse for driving bipolar pulse [14][15][16][17]. According to the published literature, the volume and weight of 10 GW bipolar pulse generators are relatively large, which limits the further application of the system.…”
Section: Introductionmentioning
confidence: 99%
“…In the last few years, high-intensity pulsed fields are getting increasingly more attention and find new applications in different domains such as biology, 1,2 industrial processes, 3 physics, 4 and military. 5 Some of them do not necessarily need high power or very high voltages-sometimes less than 10 kV can be sufficient. On the other hand, they need more controllability, flexibility, compactness, and long lifetime, which is not the case for traditional pulse generators such as Marx.…”
Section: Introductionmentioning
confidence: 99%