Short Tandem Repeat Typing by Capillary Array Electrophoresis: Comparison of Sizing Accuracy and Precision Using Different Buffer Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

1999
1999
2007
2007

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(19 citation statements)
references
References 28 publications
0
19
0
Order By: Relevance
“…Even in these cases, the differences were inferred to be caused by switches from SE machines to CE machines (8) or were hinted at rather than stated directly (27). In contrast, we in this study, and others outside the field of microbiology, have shown that different CE machines and running conditions will affect the sizing of alleles (10,25,33,38,40,41). Another microbiology study made the very general statement that separation techniques have been shown to produce different results for the same locus and therefore that special care must be taken when standardizing typing data (34).…”
Section: Discussionmentioning
confidence: 60%
See 1 more Smart Citation
“…Even in these cases, the differences were inferred to be caused by switches from SE machines to CE machines (8) or were hinted at rather than stated directly (27). In contrast, we in this study, and others outside the field of microbiology, have shown that different CE machines and running conditions will affect the sizing of alleles (10,25,33,38,40,41). Another microbiology study made the very general statement that separation techniques have been shown to produce different results for the same locus and therefore that special care must be taken when standardizing typing data (34).…”
Section: Discussionmentioning
confidence: 60%
“…Switching to another fluorescent label can alter the mobility of a DNA molecule by Ϯ0.5 bases (10), and temperature fluctuations in the laboratory housing the machine can alter mobility by up to 0.7 bases, with a temperature difference of 5°C (9). Other, potentially more serious problems include migrational deviations of the internal size standard, and we have identified one study which used an internal size standard that has been recommended not to be employed with CE machines (1,38). The calibration method used is also important, and the local Southern approach is recommended (16).…”
Section: Discussionmentioning
confidence: 99%
“…An improved system carried 96 capillaries, where the introduction of samples was done by electrokinetic injection. At an average field strength of 185 V/cm in polyacrylamide capillaries, of a 350 bp standard was separated in only 25±30 min and excellent correlation between computed and actual fragment sizes was observed [15].…”
Section: Alternative Methods Of Pcr Product Separationmentioning
confidence: 96%
“…[21][22][23] A new analytical technique, CE has been introduced into the field. 24 CE is an attractive alternative to slab gel electrophoresis in DNA analysis for the following reasons: faster separation and higher resolution, the possibility of automating sample loading and semiquantitative analysis of results. In addition to this, CE eliminates the laborintensive, time-consuming procedure of electrophoretic DNA preparation by slab gel.…”
Section: ·3 Capillary Electrophoresis For Dna Sequencingmentioning
confidence: 99%