1997
DOI: 10.1007/bf02706068
|View full text |Cite
|
Sign up to set email alerts
|

Signal analysis of fiber-optic biosensor for the detection of organophosphorus compounds in the contaminated water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

1997
1997
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“…The control of immobilization of biomolecules onto a desired area is an important technique in various applications such as biosensors, biochips, and microdevices because it can perform high throughput analysis for a short time compared with conventional methods [1][2][3]. However, selective immobilization of biomolecules ("patterning") is difficult to achieve because of nonspecific binding of biomolecules onto fabricated microdevices and the limitation of biomolecules' stability for long-term study.…”
Section: Introductionmentioning
confidence: 99%
“…The control of immobilization of biomolecules onto a desired area is an important technique in various applications such as biosensors, biochips, and microdevices because it can perform high throughput analysis for a short time compared with conventional methods [1][2][3]. However, selective immobilization of biomolecules ("patterning") is difficult to achieve because of nonspecific binding of biomolecules onto fabricated microdevices and the limitation of biomolecules' stability for long-term study.…”
Section: Introductionmentioning
confidence: 99%
“…PMSF competes with phenylacetate for the active site of AChE, thereby changing K m,1 to an the apparent value K m,1 (Equation ( 5)) [25].…”
Section: Ache Inactivation and Enzyme Kineticsmentioning
confidence: 99%
“…Choi et al developed a mathematical model for a fiber-optic biosensor to detect OPs. This model, which simulated both AChE inhibition kinetics and diffusion, was able to optimize the concentrations of AChE and its substrate [25].…”
Section: Introductionmentioning
confidence: 99%
“…At the same time, different transduction schemes, such as potentiometric [34][35][36], amperometric [37][38][39][40][41][42][43][44][45], field effect transistors [46,47], optical biosensors [48][49][50][51][52][53][54][55][56][57], fluorescent [58][59][60] and colorimetric indicators [61][62][63][64], have been explored by different research groups worldwide (see review [65][66][67][68]). AChE-based biosensors have a major drawback: since organophoshorus and carbamic pesticides, heavy metals, and detergents exert strong specific inhibition of AChE, they give a sum parameter of AChE inhibition without any qualitative or quantitative information on the individual analytes, i.e.…”
Section: Conventional Strategies For Detection Of Op Pesticidesmentioning
confidence: 99%