2004
DOI: 10.1007/s00774-003-0460-4
|View full text |Cite
|
Sign up to set email alerts
|

Significance of serum CrossLaps as a predictor of changes in bone mineral density during estrogen replacement therapy; comparison with serum carboxyterminal telopeptide of type I collagen and urinary deoxypyridinoline

Abstract: The newly developed Elecsys Beta-CrossLaps/serum assay measures C-terminal telopeptide of type I collagen and has thus been proposed as a reliable serum marker for bone resorption. We investigated its usefulness for monitoring the therapeutic effect of estrogen replacement therapy on bone turnover and bone mineral density (BMD) in patients with postmenopausal osteoporosis. Serum Beta-CTx decreased by 43.2% +/- 9.2% (mean +/- SD), and 55.1% +/- 7.0% at 3 and 6 months, respectively, after initiation of estrogen … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0
1

Year Published

2004
2004
2022
2022

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(22 citation statements)
references
References 15 publications
0
21
0
1
Order By: Relevance
“…32,33 This can be attenuated by calcium/ vitamin D supplements. 34 The DPD/cre [35][36][37] and the CTx 38,39 have been proposed as markers for bone resorption in weight loss. The higher response of DPD/cre can bear a relation to smaller bone specificity, in turn related to a decrease in urinary creatinine due to the muscle loss.…”
Section: Discussionmentioning
confidence: 99%
“…32,33 This can be attenuated by calcium/ vitamin D supplements. 34 The DPD/cre [35][36][37] and the CTx 38,39 have been proposed as markers for bone resorption in weight loss. The higher response of DPD/cre can bear a relation to smaller bone specificity, in turn related to a decrease in urinary creatinine due to the muscle loss.…”
Section: Discussionmentioning
confidence: 99%
“…91 An automated CTX assay, the Beta-CrossLaps/serum assay on the Roche Elecsys (Roche Diagnostics, Mannheim, Germany) is now available. 92 While standards for the original serum CTX-ELISA were made from antigens immunopurified from human urine; the automated assay utilizes synthetic antigens. 70 Serum and urinary CTX values are highly correlated (r > 0.8), suggesting that the antigen is similar in both types of specimens.…”
Section: Pyridinoline Crosslinksmentioning
confidence: 99%
“…These fragments are released into the circulation after the degradation of several mature collagen molecules of the bone matrix. Therefore, plasma β-CTx levels reflect the degree of bone resorption, and it has been shown that serum β-CTx could be the most useful marker for monitoring the change in bone resorption state in patients with postmenopausal osteoporosis, as well as to accurately assess the therapeutic effect of estrogen replacement therapy by predicting the future rate of BMD change [17,18].…”
Section: Introductionmentioning
confidence: 99%