2018
DOI: 10.3390/s18114026
|View full text |Cite
|
Sign up to set email alerts
|

Significant Sensitivity Improvement for Camera-Based Lateral Flow Immunoassay Readers

Abstract: Recent developments in smartphone-based strip readers have further improved the performances of lateral flow test kits. Most smartphone cameras encode an unaltered and nonlinear power-law transfer function that maps the light intensity to a pixel value; this poses some limitations for camera-based strip readers. For faint-color test lines which are almost as white such as with nitrocellulose pads, the slope of the transfer function is low. Therefore, it is difficult to differentiate between the faint test line… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
26
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 14 publications
0
26
0
Order By: Relevance
“…Thus, in the last decade, commercial models of open and closed detectors have appeared, based on optical data processing, which allow reading not only color stripes, but also fluorescent labels [6] , [76] , [79] ( Table 3 ). In addition, the advent of related software products for smartphones allows these individual mobile devices to be used to obtain rapid quantitative results without the use of additional equipment [75] , [80] . The use of mobile device platforms in quantitative LFIA formats to accurately record test results increases the efficiency of the clinic, epidemiological surveillance and disease control at the system level, and ultimately reduces the time it takes to initiate specialized treatment.…”
Section: Modern Technologies For the Quantitative Interpretation Of Tmentioning
confidence: 99%
See 4 more Smart Citations
“…Thus, in the last decade, commercial models of open and closed detectors have appeared, based on optical data processing, which allow reading not only color stripes, but also fluorescent labels [6] , [76] , [79] ( Table 3 ). In addition, the advent of related software products for smartphones allows these individual mobile devices to be used to obtain rapid quantitative results without the use of additional equipment [75] , [80] . The use of mobile device platforms in quantitative LFIA formats to accurately record test results increases the efficiency of the clinic, epidemiological surveillance and disease control at the system level, and ultimately reduces the time it takes to initiate specialized treatment.…”
Section: Modern Technologies For the Quantitative Interpretation Of Tmentioning
confidence: 99%
“…In recent years, with the emergence advent of related software products for smartphones allows these personal mobile devices to be used to obtain rapid quantitative results without the use of additional equipment [75] , [80] . The use of mobile device in quantitative LFIA formats to accurately record test results increases the efficiency of the clinic, epidemiological surveillance and disease control at the system level, and ultimately reduces the time it takes to initiate specialized treatment.…”
Section: Modern Technologies For the Quantitative Interpretation Of Tmentioning
confidence: 99%
See 3 more Smart Citations