Silicone-Coated Polypropylene Hollow-Fiber Oxygenator: Experimental Evaluation and Preliminary Clinical Use

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2004
2004
2024
2024

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(21 citation statements)
references
References 10 publications
0
21
0
Order By: Relevance
“…Intravascular hemolysis in patients with paroxysmal nocturnal hemoglobinuria produces abdominal pain, gastric and esophageal dystonia, and erectile dysfunction, with levels of plasma Hb ranging from 30 to 120 µM (in heme concentration) and up to 600 µM during paroxysms of hemolysis (28). During cardiopulmonary bypass, the levels of plasma oxyheme can rise to 150 µM (29)(30)(31)(32). The present studies suggest that these pathologically relevant levels of hemoglobinemia may be associated with endogenous NO inhibition, a vasopressor effect, and impaired organ function.…”
Section: Figurementioning
confidence: 99%
“…Intravascular hemolysis in patients with paroxysmal nocturnal hemoglobinuria produces abdominal pain, gastric and esophageal dystonia, and erectile dysfunction, with levels of plasma Hb ranging from 30 to 120 µM (in heme concentration) and up to 600 µM during paroxysms of hemolysis (28). During cardiopulmonary bypass, the levels of plasma oxyheme can rise to 150 µM (29)(30)(31)(32). The present studies suggest that these pathologically relevant levels of hemoglobinemia may be associated with endogenous NO inhibition, a vasopressor effect, and impaired organ function.…”
Section: Figurementioning
confidence: 99%
“…Though the fibers are made of a hydrophobic polymer to reduce blood plasma leakage into the fiber wall, phospholipids, lipoproteins and proteins from the plasma inevitably penetrate the submicrometer pores over time, reducing the membrane gas permeability, which can cause device failure within days (Montoya et al 1992;Federspiel and Henchir 2004). To prevent plasma leakage, some ECMO membranes are coated with a thin non-porous polymer such as silicone (Shimono et al 1997), which increases cost and reduces oxygen permeance of the membrane (Niimi et al 1997). Adverse interactions between blood and the device tubing, made of polyvinylchloride (PVC), Tygon or silicone, increases the risk of thrombosis, requiring a high level of anticoagulant administration, which can cause excessive bleeding and electrolyte-related imbalances in the patient (Stiller et al 2004;Brand 2009).…”
Section: Introductionmentioning
confidence: 99%
“…A membrane oxygenator (Excelung Binding Prime) consisting of microporous polypropylene hollow fibers was previously developed by the MERA Co. (Tokyo, Japan); in this oxygenator, the blood contact surface was coated with a 0.2 µm ultrathin silicone layer. A clinical study of this oxygenator demonstrated good gas transfer, acceptable pressure loss, low hemolysis, and good durability (19). Recently, a new heparin‐coated membrane oxygenator based on the Excelung Binding Prime was developed.…”
Section: Discussionmentioning
confidence: 99%