2011
DOI: 10.1117/1.3646208
|View full text |Cite
|
Sign up to set email alerts
|

Simple and effective method for measuring translucency using edge loss: optimization of measurement conditions and applications for skin

Abstract: Abstract. We have developed a simple and effective method for everyday measurement of translucency with a handy spectral reflectometer using edge loss. Edge loss can be used to quantify the translucency index in terms of changes in reflectance under two types of measurement conditions. Here, a measurement condition represents the pairing of an illumination area and a measurement area. As a measure of the degree of lateral spread of reflected light, the translucency index can influence the appearance of human s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 22 publications
0
12
0
Order By: Relevance
“…Vertical light transport is measured in transmission mode for which the 4 mm-thick sample is placed between light source and detector. Lateral light transport is measured in reflectance mode (detector and light source are on the same side of the sample in a 45/0 geometry) employing the spectral edge-loss difference [Yoshida et al 2011], which requires two spectral measurements both with the same detection area (circular with 2mm diameter) but with two different illuminating areas. This is achieved by using two circular apertures: one with 2mm and one with 8mm diameter.…”
Section: Color and Translucency Management 51 Measurementsmentioning
confidence: 99%
“…Vertical light transport is measured in transmission mode for which the 4 mm-thick sample is placed between light source and detector. Lateral light transport is measured in reflectance mode (detector and light source are on the same side of the sample in a 45/0 geometry) employing the spectral edge-loss difference [Yoshida et al 2011], which requires two spectral measurements both with the same detection area (circular with 2mm diameter) but with two different illuminating areas. This is achieved by using two circular apertures: one with 2mm and one with 8mm diameter.…”
Section: Color and Translucency Management 51 Measurementsmentioning
confidence: 99%
“…To specify lateral light transport we propose to use the spectrophotometric edge-loss di erence ∆L 0,1 = |L * 0 − L * 1 |, where L * 0 and L * 1 are lightness values obtained from re ectance measurements of the same sample employing two di erent measurement conditions (Yoshida et al 2011). A measurement condition is characterized by the ratio a = a d /a i , where a d is the diameter of a circular detection area and a i is the diameter of a circular illuminated area used by the spectrophotometer.…”
Section: Measuring Lateral and Vertical Light Transportmentioning
confidence: 99%
“…Note that spectrophotometric measurements are always relative to a reference measurement and factors such as the sensor's quantum e ciency or the light source's Spectral Power Distribution (SPD) are canceled out. More details including a derivation of the measurement equations from BSSRDFs is given by Yoshida et al (2011). We measure vertical light transport using a transmission setup, where the material is placed between detector and illumination (see Figure 2 right).…”
Section: Measuring Lateral and Vertical Light Transportmentioning
confidence: 99%
“…5,9 Yet, there seem to be differences in the range of colour leading to increased transparency, as pinpointed by Nishimuta et al 10 Several works have attempted to identify skin parameters important for transparency. 1,5,[11][12][13][14] Overall, they show that colour, colour homogeneity, texture and light reflection are important. Nevertheless, in almost all these studies, skin characteristics were acquired using an entire range of different devices and techniques: spectrophotometer, goniometer, Corneometer ® , confocal microscope, skin replicas, etc., and almost exclusively focussed on the cheek.…”
Section: Introductionmentioning
confidence: 96%
“…Several works have attempted to identify skin parameters important for transparency 1,5,11–14 . Overall, they show that colour, colour homogeneity, texture and light reflection are important.…”
Section: Introductionmentioning
confidence: 99%