1994
DOI: 10.1016/0378-4347(94)00132-4
|View full text |Cite
|
Sign up to set email alerts
|

Simple and sensitive assay of zonisamide in human serum by high-performance liquid chromatography using a solid-phase extraction technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
12
0

Year Published

1996
1996
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 25 publications
(12 citation statements)
references
References 6 publications
0
12
0
Order By: Relevance
“…Zonisamide was quantified in unknown samples by reverse phase HPLC (C 18 3.9 · 300 mm, 125 Å 10 lm particle size column (l-Bond-apakÔ Waters Corporation, Milford, MA, USA) with a SentryÔ Guard column, 3.9 · 20 mm (l BondapakÔ C 18, 125 Å 10 lm particle size) (SentryÔ Guard Waters Corporation, Milford, MA, USA) and ultraviolet detection at 245 nm. The mobile phase consisted of purified distilled water and methanol (70:30, v ⁄ v) with the flow rate to 1.4 mL ⁄ min (Furuno et al, 1994). Standards were prepared in canine blank serum, plasma, whole blood, and urine.…”
Section: Sample Analysismentioning
confidence: 99%
“…Zonisamide was quantified in unknown samples by reverse phase HPLC (C 18 3.9 · 300 mm, 125 Å 10 lm particle size column (l-Bond-apakÔ Waters Corporation, Milford, MA, USA) with a SentryÔ Guard column, 3.9 · 20 mm (l BondapakÔ C 18, 125 Å 10 lm particle size) (SentryÔ Guard Waters Corporation, Milford, MA, USA) and ultraviolet detection at 245 nm. The mobile phase consisted of purified distilled water and methanol (70:30, v ⁄ v) with the flow rate to 1.4 mL ⁄ min (Furuno et al, 1994). Standards were prepared in canine blank serum, plasma, whole blood, and urine.…”
Section: Sample Analysismentioning
confidence: 99%
“…Several HPLC methods have been published for the determination of ZNS in human plasma, coupled with UV [5][6][7][8][9][10][11], diode array [12], or mass spectrometry [13] detection, with different sample pre-treatment procedures: liquid-liquid extraction [5][6][7][8]11], solid phase extraction [12,13], or deproteinization [9,10]. Some of these methods allow for the simultaneous determination of ZNS with other AEDs, including the new generation AED levetiracetam (LEV) [8], lamotrigine (LTG) [10][11][12][13], oxcarbazepine's (OXC) main active metabolite monohydroxycarbamazepine (MHD) [10,12,13] and topiramate (TPM) [13].…”
Section: Introductionmentioning
confidence: 99%
“…HPLC assay, using a porous silica column, is commonly used for separation and quantification of many drugs, but it has been reported that 1.5∼2.0-μm particle non-porous silica columns provide superior performance over the 3.5∼10-μm particle porous silica columns in several parameters and the method on the non-porous silica column was faster, used less solvent, and provided greater analyte peak area [246][247][248]. Several HPLC methods using a conventional reversed-phase porous silica column for monitoring the serum concentration of ZSD have been reported [249,250]. However, these methods have common problems of long run time and high solvent consumption.…”
Section: Zonisamide (Zsd)mentioning
confidence: 99%