2009
DOI: 10.1016/j.talanta.2009.02.020
|View full text |Cite
|
Sign up to set email alerts
|

Simple sequential injection analysis system for rapid determination of microalbuminuria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…19), which shows that it has the highest sensitivity because of being strongest catalytic amplification, so it was selected to measure mAlb. Compared with the reported mAlb analysis method (Table S3), [31][32][33][34][35][37][38][39] this method is highly sensitive and easy to operate, and it is one of the best methods for detecting mAlb.…”
Section: Working Curvementioning
confidence: 99%
“…19), which shows that it has the highest sensitivity because of being strongest catalytic amplification, so it was selected to measure mAlb. Compared with the reported mAlb analysis method (Table S3), [31][32][33][34][35][37][38][39] this method is highly sensitive and easy to operate, and it is one of the best methods for detecting mAlb.…”
Section: Working Curvementioning
confidence: 99%
“…With respect to food applications, greatly advantageous SIA-system characteristics have been offered, including an easy adaptation to different analytical situations without the need for a physical reconfiguration, an automated sample injection, and a controlled dispersion. The SIA system allows for a choice of different types of liquid driver, a reproducible timing, a great capacity in relation to the solution-handling operations, and it is more flexible for its application in stopped-flow and reversed-flow operations [ 16 , 17 ]. To our knowledge, however, an automated determination of the saccharin concentration for which a SIA system is employed has not been reported; therefore, a simple and rapid SIA method for a quantitative determination of the saccharin concentration in food-product samples is proposed in the present paper.…”
Section: Introductionmentioning
confidence: 99%
“…9 Recently, Laiwattanapaisal et al reported a simple and sensitive sequential injection analysis of microalbuminuria with fluorescent detection using Albumin Blue-580. 10 However, neither the light scattering nor the fluorescent detection methods are applicable to Point-of-care testing. More sensitive screening tests are required to pre-select the samples for early diagnosis, requiring neither sophisticated instrumentation nor laboratory skill.…”
Section: Introductionmentioning
confidence: 99%