2022
DOI: 10.1049/gtd2.12491
|View full text |Cite
|
Sign up to set email alerts
|

Simulation and experimental analysis of three‐dimensional temperature distribution of ±400‐kV converter transformer valve‐side resin impregnated paper bushing under high current

Abstract: In order to cope with the current engineering demand for increasing the current-carrying capacity of resin impregnated paper (RIP) bushing, an optimization scheme of RIP bushing was proposed in this paper. Simulation and experimental studies were carried out to verify the rationality of the scheme. An improved simulation method was proposed. To ensure as much accuracy as possible, the physical model of simulation considers the influence of heat conduction, thermal convection and thermal radiation process accor… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 22 publications
0
13
0
Order By: Relevance
“…Figure 8b is the model mesh with 196,147 tetrahedral grids. The material parameters are shown in Table 3, and more detailed structure and material parameters can be found in [39, 40]. We ensure that CFEM code, ABAQUS and the novel algorithm use the same mesh, which is exported from ABAQUS, to compare the accuracy and calculation speed.…”
Section: Numerical Examplementioning
confidence: 99%
“…Figure 8b is the model mesh with 196,147 tetrahedral grids. The material parameters are shown in Table 3, and more detailed structure and material parameters can be found in [39, 40]. We ensure that CFEM code, ABAQUS and the novel algorithm use the same mesh, which is exported from ABAQUS, to compare the accuracy and calculation speed.…”
Section: Numerical Examplementioning
confidence: 99%
“…High voltage direct current (HVDC) is an important technology for long distance transmission due to its low losses, and the converter transformer valve-side bushing (CTVSB) is a key component bridging the converter transformer and thyristor value hall, which plays an important role in HVDC power transmission systems [1,2]. During operation, the bushing insulation is always subjected to a combination effects of AC, DC and multi-frequency harmonic voltages [3,4].…”
Section: Introductionmentioning
confidence: 99%
“…The harmonic frequency content and amplitude distribution of power grid disturbance are analyzed. The insulation information of high-voltage capacitive bushing is obtained using online detection, and the accurate evaluation of its insulation condition is of great significance to ensure the safe and stable operation of the transformer [7][8][9][10].…”
Section: Introductionmentioning
confidence: 99%