2019
DOI: 10.1049/joe.2018.8391
|View full text |Cite
|
Sign up to set email alerts
|

Simulation and partial discharge detection for typical defects of 10 kV cable the joint

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…More references about the PRPD for surface discharge including surface discharge on Epoxy Resin, the solid insulation used in this paper, can be found in literature, e.g. [37], [38], [39], [40], [41], [42], [43], [44], [45], [46]. Indeed, by increasing the applied voltage, the discharge number and discharge amplitude in both positive and negative half-cycles will increase accordingly for both antenna and HFCT sensor.…”
Section: ) Partial Discharge Waveform Amplitude Measurementmentioning
confidence: 99%
“…More references about the PRPD for surface discharge including surface discharge on Epoxy Resin, the solid insulation used in this paper, can be found in literature, e.g. [37], [38], [39], [40], [41], [42], [43], [44], [45], [46]. Indeed, by increasing the applied voltage, the discharge number and discharge amplitude in both positive and negative half-cycles will increase accordingly for both antenna and HFCT sensor.…”
Section: ) Partial Discharge Waveform Amplitude Measurementmentioning
confidence: 99%
“…For the PD characteristics, in 2018, Xia et al [19] conducted PD tests on various faults such as the main insulation of cable joints, and obtained the inception discharge voltage and the apparent charge. In 2020, Xia et al [20] obtained PD characteristics of typical insulation defects in 10-kV XLPE cable joints, including the phase-resolved partial discharge (PRPD)spectrum, and time-frequency (TF) spectrum.…”
Section: Introductionmentioning
confidence: 99%
“…For the PD characteristics, in 2018, Xia et al. [19] conducted PD tests on various faults such as the main insulation of cable joints, and obtained the inception discharge voltage and the apparent charge. In 2020, Xia et al.…”
Section: Introductionmentioning
confidence: 99%
“…In an empirical working situation, electric field laceration throughout these defects is reshape, exceeding unfavorable possessions upon the XLPE insulation disintegration [2]. Therefore, as PD audit has incline a cardinal device in estimate the attainment of insulation materials, the designing of PD is valuable in supposing a excelling recognition of PD development [5].…”
Section: Introductionmentioning
confidence: 99%