2012
DOI: 10.1016/j.jchromb.2012.03.006
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of 45 pesticides in fruit and vegetable using an improved QuEChERS method and on-line gel permeation chromatography–gas chromatography/mass spectrometer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(14 citation statements)
references
References 18 publications
1
12
0
1
Order By: Relevance
“…The SEC was equipped with an automatic sample injector (SIL‐20A), a Shodex CLNpak EV‐200AC SEC chromatographic column (2 mm (id) × 15 mm (L)), two pumps (LC–20AD), a column oven (CTO‐20A), an UV detector (SPD‐20A), two flow channel selection valves A and B (FCV‐12AH), a 200 μL sample loop and a data processor (CBM‐20A). The schematic diagram and operational principle of online SEC device has been reported in details . The SEC system was coupled with GC–MS/MS.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The SEC was equipped with an automatic sample injector (SIL‐20A), a Shodex CLNpak EV‐200AC SEC chromatographic column (2 mm (id) × 15 mm (L)), two pumps (LC–20AD), a column oven (CTO‐20A), an UV detector (SPD‐20A), two flow channel selection valves A and B (FCV‐12AH), a 200 μL sample loop and a data processor (CBM‐20A). The schematic diagram and operational principle of online SEC device has been reported in details . The SEC system was coupled with GC–MS/MS.…”
Section: Methodsmentioning
confidence: 99%
“…SEC has the capability of removing interferences such as pigment, polymer, and alkaloid from matrix . An online SEC–GC–MS/MS, in which SEC is added to GC–MS/MS online, is a fast, efficient, and labor‐saving system for screening residual pesticides in foods in comparison with the offline operation, which consumes more time and solvent .…”
Section: Introductionmentioning
confidence: 99%
“…Through calculation and investigation, the cost in clean-up step for one sample were $2.24 and less than $0.64 for traditional QuEChERS method [39] and the proposed QuEChERS method, respectively. What's more, the centrifugation or filtration step which was used in traditional QuEChERS method containing GCB or C18 was omitted in the proposed method [18,19,21,22,36], so it has the advantages of simplicity and rapidity. In whole, compared to other methods for the determination of OCPs in tobacco [22], water [29,[32][33][34][35], fruit and vegetable samples [36], the method in this study has the advantages of simple to operate, low cost and high clean-up ability.…”
Section: Compared With Other Methodsmentioning
confidence: 99%
“…By coupling with on-line gel permeation chromatography-gas chromatography/tandem mass spectrometry (on-line GPC-GC-MS 2 ), a method for the determination of 26 OCPs residues in tobacco was proposed. Because GPC clean-up system is connected to a GC-MS 2 system online, so it provides a fast and labor-saving analytical system for screening pesticide residues [36,37]. In addition, the using of magnetic graphene significantly simplifies the sample preparation procedure.…”
Section: Introductionmentioning
confidence: 99%
“…Many approaches for the isolation of polycyclic aromatic hydrocarbons from oil have been reported, including liquid-liquid partitioning (Cabras et al 1997;Lentza-Rizos, Avramides, and Cherasco 2001), solid phase extraction (Ferrer et al 2005), and gel permeation chromatography (Fromberg, Højgård, and Duedahl-Olesen 2007). Gel permeation chromatography is a reliable and advantageous method due to its high selectivity and capability to isolate analytes in a single injection with fully automated systems, and has been widely reported for polycyclic aromatic hydrocarbons in food (Lu et al 2012). Similarly, a number of chromatographic methods have been developed for the quantification of polycyclic aromatic hydrocarbons in food (Gratz et al 2000;Moret and Conte 2000).…”
Section: Introductionmentioning
confidence: 99%