1995
DOI: 10.1016/0003-2670(95)00336-x
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of alkali and alkaline earth metals by ion chromatography with neutral carrier-based ion-selective electrode detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1997
1997
2019
2019

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 24 publications
0
8
0
Order By: Relevance
“…ISEs with limited selectivity were used as detectors in ion chromatography or electrophoresis [154]. To reduce the selectivity and obtain more similar responses for various ions, ionophores that enhance the response to very hydrophilic ions but have a smaller effect on the response to more lipophilic ions have been used [155]. However, arrays of a small number of quite selective ISEs appear to be a viable alternative to this approach [156] and deliver more speci®c information than one nonselective electrode alone.…”
Section: Do We Need Selectivity?mentioning
confidence: 99%
See 1 more Smart Citation
“…ISEs with limited selectivity were used as detectors in ion chromatography or electrophoresis [154]. To reduce the selectivity and obtain more similar responses for various ions, ionophores that enhance the response to very hydrophilic ions but have a smaller effect on the response to more lipophilic ions have been used [155]. However, arrays of a small number of quite selective ISEs appear to be a viable alternative to this approach [156] and deliver more speci®c information than one nonselective electrode alone.…”
Section: Do We Need Selectivity?mentioning
confidence: 99%
“…Leaching can be avoided by covalent attachment of membrane components to the polymer backbone [202,203]. Depending on the very system, the anchoring of both the ionophore and the ion exchanger sites may [202] or may not [155,203] affect the response slope. To obtain a robust inner reference system, use of the lipophilic complex of a redox-active ion, such as of Ag , in connection with a Ag wire as solid contact, has been proposed [204,205].…”
Section: Size Limitsmentioning
confidence: 99%
“…So, it is necessary to establish a rapid and sensitive method that can quantitatively determine a variety of metal ions simultaneously. Up to now, many methods have been proposed to determine metal ions, such as atomic absorption spectrometry (AAS) [6][7][8][9][10], inductively coupled plasma atomic emission spectrometry (ICP-AES) [11][12][13][14][15][16], spectrophotometry [17,18], high performance liquid chromatography [19], reversed-phase liquid chromatography [20], and ion chromatography [21]. The reinto spectrophotometer method is widely used for its simpleness.…”
Section: Introductionmentioning
confidence: 99%
“…The use of weak, e.g. carboxylic-based silica cationexchangers allows the elution of Ba 2+ and Sr 2+ by mild acidic complexing agents such as tartaric acid as the eluents and nonsuppressed conductivity detection [8] or ion selective electrode detection [9], but with the high LOD imposed by the detection technique. Only new philosophies and technology in stationary phases development can answer to this demand [10] , spectroscopic techniques such as IPC-MS are usually preferred [11,12].…”
Section: Introductionmentioning
confidence: 99%