2021
DOI: 10.1016/j.talanta.2020.121539
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of direct yellow 50, tryptophan, carbendazim, and caffeine in environmental and biological fluid samples using graphite pencil electrode modified with palladium nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(12 citation statements)
references
References 53 publications
0
12
0
Order By: Relevance
“…Herein, PdNPs/rGO/GCE was fabricated by facile two-step electrodeposition to detect AA, DA, and UA simultaneously. Although the preparation of PdNPs/rGO nanocomposites has been reported [ 19 21 ], most of them are prepared through a multistep complex process, which not only involves chemicals that may cause health and environmental risks but also contains long-time consumption. In addition to good catalytic activity and rapid response (≤5 s), the sensor prepared in this work also exhibited high reproducibility and stability.…”
Section: Introductionmentioning
confidence: 99%
“…Herein, PdNPs/rGO/GCE was fabricated by facile two-step electrodeposition to detect AA, DA, and UA simultaneously. Although the preparation of PdNPs/rGO nanocomposites has been reported [ 19 21 ], most of them are prepared through a multistep complex process, which not only involves chemicals that may cause health and environmental risks but also contains long-time consumption. In addition to good catalytic activity and rapid response (≤5 s), the sensor prepared in this work also exhibited high reproducibility and stability.…”
Section: Introductionmentioning
confidence: 99%
“…The CBZ electrochemical reaction occurs through the deprotonation of the nitrogen atoms of the benzimidazole ring and carbamate group, forming an imine as a redox product. According to results obtained in the previous study and references reported in the literature [25,26] an oxidation mechanism was proposed for CBZ (Scheme 1) involving the transfer of two protons and two electrons.…”
Section: Optimization Of the Sensor And Analytical Parameters Of The ...mentioning
confidence: 65%
“…The objectives of the work by Wong et al [ 81 ] were to develop a PGE-based electrochemical sensor with palladium nanoparticles (PGE-PdNPs) and to investigate its ability to determine CF in different samples. The PGE-PdNPs had good analytical performance for the detection of CF in the presence of other compounds such as direct yellow 50, tryptophan, and carbendazim.…”
Section: Discussionmentioning
confidence: 99%