1997
DOI: 10.1007/bf02034256
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of environmental α-radionuclides using liquid scintillation counting combined with time interval analysis (TIA) and pulse shape discrimination (PSD)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

1999
1999
2007
2007

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 5 publications
0
10
0
Order By: Relevance
“…The measuring system consists of an α-LSC (Ordera 8100AB) called Perals, a multi-channel analyzer (MCA, Seiko EG&G, 7800), and a personal computer (Epson PC-486 SE) with a timer/counter module (Contec, TIR-6) having a time resolution of 0.1 ms. Details of the assembly have been presented in elsewhere [3,4,5]. The Perals spectrometer contains a pulse shape discrimination (PSD) circuit to reject pulses caused by β-particles and γ-rays and to extract pure α-pulses.…”
Section: Measurement Systemmentioning
confidence: 99%
See 3 more Smart Citations
“…The measuring system consists of an α-LSC (Ordera 8100AB) called Perals, a multi-channel analyzer (MCA, Seiko EG&G, 7800), and a personal computer (Epson PC-486 SE) with a timer/counter module (Contec, TIR-6) having a time resolution of 0.1 ms. Details of the assembly have been presented in elsewhere [3,4,5]. The Perals spectrometer contains a pulse shape discrimination (PSD) circuit to reject pulses caused by β-particles and γ-rays and to extract pure α-pulses.…”
Section: Measurement Systemmentioning
confidence: 99%
“…9(b), the number of correlated total events is obtained from the initial exponential decay curve over the noise (horizontal line), which is due to random events. The exponential decay component was extracted from the data for the correlated events or for analysis of the radionuclide after correction with the overall yield from the 225 Ra-tracer [1,2,3,4,5,6]. It should be emphasized that the use of a 225 Ra-tracer is helpful in determining the other radium isotopes.…”
Section: Effects Of Purging the Scintillator Cocktail With Nitrogen Gasmentioning
confidence: 99%
See 2 more Smart Citations
“…6 The PERALS spectrometer contains a pulse shape discrimination (PSD) circuit combined with optically excellent efficiency containing a single photomultiplier tube and reflector surface. After optimizing the pulse shape discrimination level, the spectrometer provides either analog output signal of both a-and ~/y-particles or a-particle alone, dependent on the different pulse shapes of a-and [3/y-radiations.…”
Section: Alpha-spectrometry With Liquid Scintillation and Tiaanalysismentioning
confidence: 99%