2009
DOI: 10.1016/j.jpba.2008.12.011
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of sulphamethoxazole and trimethoprim in powder mixtures by attenuated total reflection-Fourier transform infrared and multivariate calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
16
0
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 37 publications
(17 citation statements)
references
References 40 publications
0
16
0
1
Order By: Relevance
“…Thus, modern infrared spectroscopy has gained acceptance as a reliable tool for quantitative analysis (Settle 1997). Different accessories with diffuse or attenuated reflectance operating in mid-infrared and refl ectance or transmittance mode operating in near infrared enabled the analysis of samples in many different forms such as solutions, powders and intact tablets (Kipouros et al 2006, Armenta et al 2005, Boyer et al 2006, Silva et al 2009, Ferreira et al 2013. In some instances, previous sample treatment is unnecessary and the results are obtained in real time (Lin et al 2006).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, modern infrared spectroscopy has gained acceptance as a reliable tool for quantitative analysis (Settle 1997). Different accessories with diffuse or attenuated reflectance operating in mid-infrared and refl ectance or transmittance mode operating in near infrared enabled the analysis of samples in many different forms such as solutions, powders and intact tablets (Kipouros et al 2006, Armenta et al 2005, Boyer et al 2006, Silva et al 2009, Ferreira et al 2013. In some instances, previous sample treatment is unnecessary and the results are obtained in real time (Lin et al 2006).…”
Section: Introductionmentioning
confidence: 99%
“…In practice, multivariate regression model optimization is based on the identifi cation of a complete data subset that will produce the lowest prediction error (Chen et al 2008). Several approaches have been proposed for selection of optimal set of spectral regions for multivariate calibration such as genetic algorithms, interval PLS (iPLS) and synergy PLS (siPLS) (Silva et al 2009, Friedel et al 2013, Leardi and Nørgaard 2004, Navea et al 2005, Bogomolov and Hachey 2007, Menezes et al 2014, Ruschel et al 2014. Interval PLS allows the construction of models with a spectral interval, and Root Mean Square Error of Cross Validation (RMSECV) values can be used as the criterion to evaluate the prediction ability of this interval.…”
Section: Introductionmentioning
confidence: 99%
“…Desse ponto de vista, tem-se buscado alternativas para o controle de qualidade de medicamentos que ofereçam maior rapidez na análise, baixo ou ausente consumo de solventes e consequente menor geração de resíduos, mínimo preparo da amostra e menor custo (PASQUINI, 2003;DOU et al, 2007;SILVA et al, 2009). …”
Section: Introductionunclassified
“…The methods investigating feed premixes are mainly based on enzyme-linked immuneabsorbent assays, ELISAs (Jimenez et al, 2009), or high performance liquid chromatography methods, combined or not, with tandem mass spectrometry (Croubels et al, 2002;Boscher et al, 2010;Lopes et al, 2012). Nevertheless, the methods suggested to date for the simultaneous determination of SASand TMP require either a long and tedious analysis protocol (DeAngelis et al, 1990;Renew and Huang, 2004), or more explicit instrumentation, like an FT-IR spectrometer (Silva et al, 2009), capillary electrophoresis system equipped with photodiode array detector (Farooq et al, 2009), or LC-MS/MS set-up (Boscher et al, 2010;Lopes et al, 2012).…”
Section: Introductionmentioning
confidence: 99%