2007
DOI: 10.1016/j.jchromb.2007.04.025
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of trans-resveratrol-3-O-glucoside and its two metabolites in rat plasma using liquid chromatography with ultraviolet detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
13
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 19 publications
0
13
0
Order By: Relevance
“…Using this method, the limit of detection for trans-resveratrol in this study was as low as 0.1 ng mL -1 , which is lower than the sensitivity reported by Juan et al [10] (250 ng mL -1 ), Chen et al [11] (66 ng mL -1 ), Wang et al [12] (35.5 ng mL -1 ), Boocock et al [13] (5 ng mL -1 ), Meng et al [14] (12.5 ng mL -1 ), He et al [15] (20 ng mL -1 ), Zhou et al [16] (40 ng mL -1 ), Huang et al [17] (58.5 ng mL -1 ), Juan et al [18] (2.3 ng mL -1 ) and Bernardes et al [19] (100 ng mL -1 ). In addition, this method requires only a very small amount of sample (100 lL), and the retention time of the method is 3.2 min compared with times of 8-25 min reported for other methods.…”
mentioning
confidence: 58%
See 3 more Smart Citations
“…Using this method, the limit of detection for trans-resveratrol in this study was as low as 0.1 ng mL -1 , which is lower than the sensitivity reported by Juan et al [10] (250 ng mL -1 ), Chen et al [11] (66 ng mL -1 ), Wang et al [12] (35.5 ng mL -1 ), Boocock et al [13] (5 ng mL -1 ), Meng et al [14] (12.5 ng mL -1 ), He et al [15] (20 ng mL -1 ), Zhou et al [16] (40 ng mL -1 ), Huang et al [17] (58.5 ng mL -1 ), Juan et al [18] (2.3 ng mL -1 ) and Bernardes et al [19] (100 ng mL -1 ). In addition, this method requires only a very small amount of sample (100 lL), and the retention time of the method is 3.2 min compared with times of 8-25 min reported for other methods.…”
mentioning
confidence: 58%
“…Several extraction methods have been described, such as solid-phase extraction (SPE) [10,12,18], methanol [12,13] or acetonitrile [11,15,16] as protein precipitants, and liquid-liquid extraction with ethyl acetate [14,17]. In this study, ethyl acetate was used as the extraction solvent to obtain high sensitivity and avoid matrix interference.…”
Section: Methods Development and Optimizationmentioning
confidence: 99%
See 2 more Smart Citations
“…or water-miscible organic solvents [3][4][5][6][7][8][9]. Although all of these procedures can be used in discarding proteins prior to analysis…”
Section: Introductionmentioning
confidence: 99%