Simultaneous Estimation of Sacubitril and Valsartan in Pharmaceutical Dosage Form by Development and Validation of Stability Indicating Chromatographic Method

Abstract: This study aims to develop and validate a stability indicating HPLC method for simultaneous estimation of sacubitril and valsartan in pharmaceutical dosage form. Sacubitril and valsartan separation was achieved by LC-20 AT C 18 (250mm x 4.6 mm) column and buffer (potassium phosphate, pH 3.0): methanol (50:50) as mobile phase, at a flow rate of 1 ml/min (milliliter per minute). Detection was carried out at 224 nm (nanometer). The different HPLC experimental parameters were optimized and the method was validated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 10 publications
0
1
0
Order By: Relevance
“…It is interesting to observe HPLC had been continuously used in development of stability indicating studies of sacubitril and valsartan ( Ahmed et al., 2017 ; Patel et al., 2017 ; Mishara et al., 2017 ; Naazneen and Sridevi, 2017 ; Jyothi and Umadevi, 2018 ; Moussa et al., 2018 ). Various combinations of mobile phases were used to achieve better separation for sacubitril, valsartan and their impurities.…”
Section: Stability Indicating Assaysmentioning
confidence: 99%
“…It is interesting to observe HPLC had been continuously used in development of stability indicating studies of sacubitril and valsartan ( Ahmed et al., 2017 ; Patel et al., 2017 ; Mishara et al., 2017 ; Naazneen and Sridevi, 2017 ; Jyothi and Umadevi, 2018 ; Moussa et al., 2018 ). Various combinations of mobile phases were used to achieve better separation for sacubitril, valsartan and their impurities.…”
Section: Stability Indicating Assaysmentioning
confidence: 99%
“…The primary matter of valsartan, valeryl 4-hydroxy valsartan, has no medicine activity. Literature search reveals that only two analytical methods were reported for simultaneous estimation of sacubitril and valsartan from rat plasma using LC-MS/MS and from a synthetic mixture using HPLC [12][13][14][15][16][17][18][19][20]. Hence a simple, rapid, sensitive and accurate stability indicating HPLC method was developed for the simultaneous estimation of sacubitril and Valsartan from rat plasma (Figures 1 & 2).…”
Section: Drug Profilementioning
confidence: 99%