AimThis study aimed to investigate tolerance dose to organs at risk (OARs) as well as degree of conformity and homogeneity for head and neck cancer patients by using simultaneous integrated boost intensity-modulated radiotherapy technique (SIB IMRT).Materials and methodsThis study analysed 15 head and neck cancer patients receiving treatment using inverse planned SIB IMRT technique. Using a beam energy of 6 MV, two dose levels of 70 and 55·4 Gy were used to treat the tumour. Doses of 2 Gy in 35 fractions and 1·68 Gy in 33 fractions were simultaneously delivered for effective planning target volume (PTV1) and boost planning target volume (PTV2), respectively.ResultsDose distribution in PTV and critical organs lies within tolerance dose guidelines protecting spinal cord, brain stem, optic chiasm, optic nerve, thus reducing the risk of damage to normal tissues. Minor deviation from tolerance limit was observed for parotid glands. This technique provided highly conformal and homogenous dose distribution as well as better sparing of OARs, hence verifying quality assurance results to be satisfactory.FindingsSIB IMRT technique offers best solution for preserving organ function by keeping dose below tolerance level. Treatment of head and neck carcinoma using SIB IMRT is feasible, more efficient, and dose escalation is achieved in a single plan.