2013
DOI: 10.1007/s10404-012-1130-4
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous measurement of dissolved oxygen concentration and velocity field in microfluidics using oxygen-sensitive particles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 18 publications
0
9
0
Order By: Relevance
“…Such dyes can be incorporated into the media and flowed through the devices, [64][65][66] patterned as spots or thin films that are integrated into the device at the time of fabrication, 29,[67][68][69] or as particles or beads that are introduced into the device after assembly. [70][71][72] In this study, we used a solution of RTDP in media in order to measure oxygen temporally and spatially throughout the LAMPS volume. Although RTDP concentrations higher than 0.2 mM were reported to be phototoxic, lower concentrations were found to be cell compatible.…”
Section: Measuring Oxygen Tension In Lampsmentioning
confidence: 99%
“…Such dyes can be incorporated into the media and flowed through the devices, [64][65][66] patterned as spots or thin films that are integrated into the device at the time of fabrication, 29,[67][68][69] or as particles or beads that are introduced into the device after assembly. [70][71][72] In this study, we used a solution of RTDP in media in order to measure oxygen temporally and spatially throughout the LAMPS volume. Although RTDP concentrations higher than 0.2 mM were reported to be phototoxic, lower concentrations were found to be cell compatible.…”
Section: Measuring Oxygen Tension In Lampsmentioning
confidence: 99%
“…The containers contain three inlets for the input of oxygen and nitrogen gases, as well as an insert for the oxygen meter (Hanna Instruments 98193) which was used to monitor dissolved oxygen (DO). One gas outlet was fitted with the rubber lid for free flow of gases into the chamber …”
Section: Methodsmentioning
confidence: 99%
“…One gas outlet was fitted with the rubber lid for free flow of gases into the chamber. 37 For calibration of oxygen in a hydrogel sphere, the alginate solution was mixed with 10−20 μL of FNOPs and stirred for 5 min using a magnetic stirrer and then the hydrogels of size ∼750 μm were generated by using the technique as specified in section 2.1.2.2. The generated hydrogels were collected and pipetted evenly onto the well gasket filled with the alginate.…”
Section: Acs Applied Materials and Interfacesmentioning
confidence: 99%
“…H. D. Kim et al [61] used a conventional microparticle image velocimetry method for performing simultaneous measurements of dissolved oxygen concentration (DOC) and velocity fields. DOC was determined by applying oxygen-sensitive particles, which were produced by the dispersion polymerization method.…”
Section: Combination Of Particle-based Oxygen Sensing With Flow Velocimetrymentioning
confidence: 99%