2016
DOI: 10.1364/optica.3.000897
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous multiview capture and fusion improves spatial resolution in wide-field and light-sheet microscopy

Abstract: Most fluorescence microscopes are inefficient, collecting only a small fraction of the emitted light at any instant. Besides wasting valuable signal, this inefficiency also reduces spatial resolution and causes imaging volumes to exhibit significant resolution anisotropy. We describe microscopic and computational techniques that address these problems by simultaneously capturing and subsequently fusing and deconvolving multiple specimen views. Unlike previous methods that serially capture multiple views, our a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
81
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 59 publications
(82 citation statements)
references
References 37 publications
1
81
0
Order By: Relevance
“…The use of other DNA repairs foci like RAD51, MDC1 for DSBs and XRCC1, for example for non-DSBs maybe can help toward the optimization of detection according to the type of genotoxic stress [58]. In addition, very recent advances in fluorescence microscopy harnessing previously unused fluorescence or DNA autofluorescence by a 532-nm laser excitation [59] may improve the detection of protein distributions especially located in a complex form [60].…”
Section: Discussionmentioning
confidence: 99%
“…The use of other DNA repairs foci like RAD51, MDC1 for DSBs and XRCC1, for example for non-DSBs maybe can help toward the optimization of detection according to the type of genotoxic stress [58]. In addition, very recent advances in fluorescence microscopy harnessing previously unused fluorescence or DNA autofluorescence by a 532-nm laser excitation [59] may improve the detection of protein distributions especially located in a complex form [60].…”
Section: Discussionmentioning
confidence: 99%
“…In quadruple-view deconvolution, we start with the additive RLD update, finding as previously reported 11 that this method yields better reconstructions than the alternating joint deconvolution update used for diSPIM: Finally, setting b to be the unmatched WB filter appropriate for each view provides the fastest update, as for dual-view and single-view microscopes.…”
Section: Quad-view Deconvolutionmentioning
confidence: 99%
“…In addition to deblurring, deconvolution can be used to combine multiple independent measurements taken on the same sample to produce an improved overall estimate of the sample 5 . This approach is especially useful in reconstructing super-resolution images in structured illumination microscopy 6,7 or in performing joint deconvolution to improve spatial resolution in multiview light-sheet microscopy [8][9][10][11][12] .…”
Section: Introductionmentioning
confidence: 99%
“…A line of knock-in parasites was constructed in which the single genomic copy of TgAPR1 was replaced with TgAPR1-mCherryFP ( Fig. 11) by homologous recombination (Wu et al, 2016).…”
Section: Counting Molecules Of a Protein Component Of A Putative Micrmentioning
confidence: 99%