2021
DOI: 10.1002/adfm.202100066
|View full text |Cite
|
Sign up to set email alerts
|

Single Cell Bioprinting with Ultrashort Laser Pulses

Abstract: Tissue engineering requires the precise positioning of mammalian cells and biomaterials on substrate surfaces or in preprocessed scaffolds. Although the development of 2D and 3D bioprinting technologies has made substantial progress in recent years, precise, cell‐friendly, easy to use, and fast technologies for selecting and positioning mammalian cells with single cell precision are still in need. A new laser‐based bioprinting approach is therefore presented, which allows the selection of individual cells from… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

5
23
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 28 publications
(28 citation statements)
references
References 60 publications
5
23
0
Order By: Relevance
“…Under appropriate conditions, single cells can be reliably transferred with a high survival rate after transfer through the entire pulse duration range. This agrees very well with our previous findings obtained for a laser pulse duration of 0.6 ps [22,23]. Nevertheless, it is mandatory to investigate the long-term cell viability of ps-laser printed cells in a future study.…”
Section: Introductionsupporting
confidence: 92%
See 4 more Smart Citations
“…Under appropriate conditions, single cells can be reliably transferred with a high survival rate after transfer through the entire pulse duration range. This agrees very well with our previous findings obtained for a laser pulse duration of 0.6 ps [22,23]. Nevertheless, it is mandatory to investigate the long-term cell viability of ps-laser printed cells in a future study.…”
Section: Introductionsupporting
confidence: 92%
“…Due to the lower mass-density, living human mesenchymal stem cells (hMSC, SCP1 cell line) were suspended at the hydrogel surface (Figure 1 left). To visualize and investigate the process dynamics, including cavitation bubble expansion and subsequent jet propagation, pump-probe [30] time-resolved imaging observation was carried out, as described previously [23]. Briefly, the transfer process was illuminated by a 28 ns white-light pulse (Nanolite KL-L, High-Speed Photo-Systeme, Wedel, Germany) and then was captured with an imaging system comprising a microscope objective (Mitutoyo Plan Apo 5×/0.14, Japan), a tube lens (TTL200-A, Thorlabs, Bergkirchen, Germany), and a CCD1 camera (PCO, Pixefly USB, Kelheim, Germany).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations