2017 10th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI) 2017
DOI: 10.1109/cisp-bmei.2017.8302235
|View full text |Cite
|
Sign up to set email alerts
|

Single channel brain-computer interface control system based on TGAM module

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
4
2
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 6 publications
0
7
0
Order By: Relevance
“…First of all, it may be the problem of development cost that TGAM, as a single-node EEG device, does not have good enough antinoise and data analysis step. No matter, in the experiment of this paper or the experimental data in some articles [21], the attention data calculated by the module's own algorithm is very unsatisfactory in practical application, with large fluctuations, high delay, and low accuracy (Figure 1). Some research projects have used large [22], but the results have been extremely limited.…”
Section: The Design Of Data Transmission Via the Tgammentioning
confidence: 87%
“…First of all, it may be the problem of development cost that TGAM, as a single-node EEG device, does not have good enough antinoise and data analysis step. No matter, in the experiment of this paper or the experimental data in some articles [21], the attention data calculated by the module's own algorithm is very unsatisfactory in practical application, with large fluctuations, high delay, and low accuracy (Figure 1). Some research projects have used large [22], but the results have been extremely limited.…”
Section: The Design Of Data Transmission Via the Tgammentioning
confidence: 87%
“…In addition, Physical Reconfiguration is made using a TGAM1 sensor for acquisition of dolphin brain signals and a Bluetooth HC06 B26782h module for wireless data transmission. This sensor has different connections, but among the most important are the power, transmission, reception, and electrode connections [30]. TGAM1 EEG Sensor uses a main electrode called EEG signal pad made of silver, which is a good conductor.…”
Section: Methodsmentioning
confidence: 99%
“…TGAM1 EEG Sensor uses a main electrode called EEG signal pad made of silver, which is a good conductor. The design of this sensor holds impedance below 5 KΩ in each electrode because both the sort the electrodes' material and the dolphin's skin under salt water can reduce the impedance and increase conductivity [30,31]. Ground electrodes and their function is to make a difference between EEG signal pad and the ambient noise.…”
Section: Methodsmentioning
confidence: 99%
“…TGAM1 module is connected directly to a dry electrode, it has an EEG channel with three contacts: EEG, REF and GND. Moreover, it has an incorrect setting signaling that detects through the "Poor Signal" warning if communication with the user's head should be reestablished, and it is also provided with advanced filtering technology with high immunity to noise [23]. Its low power consumption is suitable for portable battery-powered applications, since its maximum power consumption is 15 mA at 3.3 V. On the other hand, a Bluetooth connection is used for data transmission to 57600 bauds [24].…”
Section: Theoretical Basismentioning
confidence: 99%