2021
DOI: 10.3390/molecules26123697
|View full text |Cite
|
Sign up to set email alerts
|

Single-Sided Portable NMR Investigation to Assess and Monitor Cleaning Action of PVA-Borax Hydrogel in Travertine and Lecce Stone

Abstract: In this work, we investigated the potential of PVA-borax hydrogel for cleaning limestones and the dependence of the cleaning on the porosity of the rock and on the action time of the hydrogel treatment. Towards this goal, we used a nuclear magnetic resonance (NMR) spectrometer, developed for non-invasive and non-destructive applications on cultural heritage. T2-NMR parameters were quantified on different samples of Lecce stone and Travertine cut perpendicular (Pe) and parallel (Pa) to the bedding planes under … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 59 publications
0
11
0
Order By: Relevance
“…This result may suggest that the PVA-based hydrogel did not completely remove the metal corrosion products from the stone. In addition, the fact that the T 1 did not return to the initial values may also suggest that the gel used has left residues in the pores, as observed in previous studies [ 12 , 29 ]. In particular, in Travertine soiled with corrosion products from the penny (Travertine 1) the T 1 and T 2 distributions have the same behavior with both T 1 and T 2 mean values that did not return to their original value after the cleaning process ( Figure 3 ).…”
Section: Resultsmentioning
confidence: 78%
See 4 more Smart Citations
“…This result may suggest that the PVA-based hydrogel did not completely remove the metal corrosion products from the stone. In addition, the fact that the T 1 did not return to the initial values may also suggest that the gel used has left residues in the pores, as observed in previous studies [ 12 , 29 ]. In particular, in Travertine soiled with corrosion products from the penny (Travertine 1) the T 1 and T 2 distributions have the same behavior with both T 1 and T 2 mean values that did not return to their original value after the cleaning process ( Figure 3 ).…”
Section: Resultsmentioning
confidence: 78%
“…The two T 1 and T 2 components detected for all three samples, suggest that two main different pore size compartments exist in the stones. In contrast to our previous work [ 12 ], we investigated samples at relative humidity (RH) value equal to 50 ± 3%. For this reason we did not detect the long T 2 component (around few or tens of ms) obtained in the study performed at RH = 94% [ 12 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations