2018
DOI: 10.1007/978-981-10-7629-9_72
|View full text |Cite
|
Sign up to set email alerts
|

SiO x /TiO y /C z H t Composite Coatings Prepared by Magnetron Co-sputtering on Substrate Paper

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
147
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 101 publications
(155 citation statements)
references
References 10 publications
5
147
0
Order By: Relevance
“…The on/off ratio of the graphene-only device is ≈3.5, which is comparable to previous reports. [34,37,44] The positive Dirac voltage (V Dirac ) of 60 V indicates a p-type character of the pristine graphene, [37,45] which is in agreement with the Raman shift. The photoresponse of the pristine graphene is negligible in the white light illumination condition, as shown in Figure S6 in the Supporting Information.…”
Section: Interface Interactionsmentioning
confidence: 58%
“…The on/off ratio of the graphene-only device is ≈3.5, which is comparable to previous reports. [34,37,44] The positive Dirac voltage (V Dirac ) of 60 V indicates a p-type character of the pristine graphene, [37,45] which is in agreement with the Raman shift. The photoresponse of the pristine graphene is negligible in the white light illumination condition, as shown in Figure S6 in the Supporting Information.…”
Section: Interface Interactionsmentioning
confidence: 58%
“…[151][152][153][154][155][156] Xia et al [157] demonstrated a single-layer and few-layer graphene-based transistor photodetector with ultrafast photoresponse characteristics, wide optical absorption wavelength, and good internal quantum efficiency. Although graphene photodetectors exhibit excellent photodetector behavior, [158][159][160][161] it is difficult to open zero bandgaps, and low light absorption [162][163][164] (only 2.3% light absorptivity) limits its application in photodetection devices. Subsequently, many 2D semiconductor materials were successively prepared and widely used in the field of photodetectors and exhibited good optical responsiveness and a fast response rate.…”
Section: Application Of 2d Materials On Photodetectorsmentioning
confidence: 99%
“…Infliximab [57][58][59][60] TNF-α, VEGF PEDF [61][62][63][64] VEGF IP-10 [65][66][67][68] VEGF, bFGF H-KI20 [69] VEGF Canstatin [70] VEGF, HIF, TNF-α Netrins [71][72][73][74] VEGF, PEDF, NK-κB p65 SERPINA3K [75,76] VEGF, TNF-α, PEDF Ascorbic acid [77][78][79][80][81] VEGF, MMP-9 EGCG [82][83][84][85] VEGF, COX-2, MMPS, NF-κB, IL-1β SAHA [86,87] VEGF, bFGF, TGF-β1, EGF, TSP-1, TSP-2, ADAMTS-1 EEDK [88] VEGF, FGF, IL-6, MMP-2…”
Section: Classification Drugs Main Targetsmentioning
confidence: 99%
“…The specific mechanisms include reducing the expression of pro-angiogenic and pro-inflammatory factors, TNF-α and VEGF, and enhancing the expression of the anti-angiogenic factor, PEDF. [75] Zhou et al tested SERPINA3K on the CNV model of rat. The SERPINA3K was injected topically three times a day.…”
Section: Serpina3kmentioning
confidence: 99%