2012
DOI: 10.1016/j.apmr.2012.06.005
|View full text |Cite
|
Sign up to set email alerts
|

Six-Minute Walk Test in Children With Cerebral Palsy Gross Motor Function Classification System Levels I and II: Reproducibility, Validity, and Training Effects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
32
0
7

Year Published

2014
2014
2022
2022

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 80 publications
(40 citation statements)
references
References 33 publications
1
32
0
7
Order By: Relevance
“…The results provide evidence that the 6MRT is a reliable test for children and youth with CP classified as GMFCS levels III and IV. These results are in agreement with studies evaluating the 6MWT in children with CP who are able to walk (Nsenga Leunkeu et al, 2012). However, the distance covered with the racerunner systematically increased every test, indicating a learning effect when performing the 6MRT.…”
supporting
confidence: 82%
See 1 more Smart Citation
“…The results provide evidence that the 6MRT is a reliable test for children and youth with CP classified as GMFCS levels III and IV. These results are in agreement with studies evaluating the 6MWT in children with CP who are able to walk (Nsenga Leunkeu et al, 2012). However, the distance covered with the racerunner systematically increased every test, indicating a learning effect when performing the 6MRT.…”
supporting
confidence: 82%
“…We therefore developed a novel test to measure racerunner capability based on the 6-minute walking test (6MWT) (American Thoraxic Society, 2002), which is a valid and reliable test for measuring walking capability in children with CP who are able to walk (Maher et al, 2008;Thompson et al, 2008;Nsenga Leunkeu et al, 2012). During the 6-Minute Racerunner Test (6MRT) children use the racerunner to propel themselves forward for 6 min on an oval track.…”
mentioning
confidence: 99%
“…Assistive devices can be used. Construct Validity-Valid measure of cardiovascular fitness for children with CP GMFCS levels I and II [55] Poor for GMFCS IV and V Poor for GMFCS IV and V Not established COPM [42] Performance level individualized outcome measure-completed by child or parent proxy in semi-structured interview. Clients identify and rate importance of up to five goals in the areas of self-care, productivity and leisure.…”
Section: Tools Used With Children At Gmfcs IV and V With Other Intervmentioning
confidence: 99%
“…Em relação ao TC6, pesquisas mostram sua confiabilidade para avaliar a potência aeró-bia e detectar adaptações cardiorrespiratórias em indivíduos deambuladores com PC; foi estabelecida uma confiabilidade com o IGE, além de ser de fácil aplicação e compreensão pelos participantes (19,25,35,50) . Em nosso estudo, o GI apresentou aumento significante na distância percorrida no TC6 e diminuição do IGE, o que condiz com menor gasto energéti-co e sugere maior resistência muscular na marcha após o protocolo de condicionamento nesses indivíduos.…”
Section: Discussionunclassified