1993
DOI: 10.1016/0003-4975(93)90477-y
|View full text |Cite
|
Sign up to set email alerts
|

Skeletal muscle ventricles: Left ventricular apex to aorta configuration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
11
0

Year Published

1994
1994
2013
2013

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 28 publications
(12 citation statements)
references
References 22 publications
1
11
0
Order By: Relevance
“…4 It has been used extensively in the assessment of cardiac assist devices. 5 Another potential benefit of an increased MADP is an improvement in coronary artery blood flow. The mean diastolic blood flow through the left anterior descending coronary artery was therefore measured.…”
Section: Indices Of the Effectiveness Of Counterpulsationmentioning
confidence: 99%
See 1 more Smart Citation
“…4 It has been used extensively in the assessment of cardiac assist devices. 5 Another potential benefit of an increased MADP is an improvement in coronary artery blood flow. The mean diastolic blood flow through the left anterior descending coronary artery was therefore measured.…”
Section: Indices Of the Effectiveness Of Counterpulsationmentioning
confidence: 99%
“…6 SMVs provide category 2 assist, and the hemodynamic performance of several configurations has been demonstrated. 5,[7][8][9][10] Previous SMV models have used linings made from synthetic materials, autologous pericardium, 11 or aortic homograft. 12 The current model includes a lining made from pulmonary artery homograft.…”
Section: Smv Designmentioning
confidence: 99%
“…Small experimental SMVs with a cavity of 25 mL with less wall stress (Laplace's law), without power-increasing drug support, and without a pumping chamber were able to work up to 4 years, 12 but it is still to be proved whether these types of sack ventricles 7,11,12 will work in larger sizes of Ϸ100 to 200 mL without any drug support.…”
Section: Pumping Chambermentioning
confidence: 99%
“…They pumped for up to 4 years in the circulation. [5][6][7][8][9][10][11][12] These SMVs (sack ventricles) in dogs pumped with low stroke work because of their small chamber volume of 25 mL. To simulate a stroke volume of Ͼ1 L/min, larger SMVs had to be built.…”
mentioning
confidence: 99%
“…SMVs and BMHs basically have two main limitations: firstly muscle damage after electrical muscle fiber transformation from a fast twitched into a slow twitched non-fatigue muscle and secondly thromboembolic complications from the blood contacting surface especially when a muscular blood pump works on demand. Former investigators developed sack-ventricles within circulation in dogs pumping up to 4 years [1][2][3][4][5]. …”
Section: Introductionmentioning
confidence: 99%