2016
DOI: 10.1016/j.jct.2016.06.014
|View full text |Cite
|
Sign up to set email alerts
|

Solubility determination and thermodynamic models for dehydroepiandrosterone acetate in mixed solvents of (ethyl acetate + methanol), (ethyl acetate + ethanol) and (ethyl acetate + isopropanol)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
128
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 103 publications
(128 citation statements)
references
References 22 publications
0
128
0
Order By: Relevance
“…The solid-liquid phase equilibrium of ACET in (acetone + methanol), (acetone + ethanol), (acetone + 1-butanol) and (acetone + isopropanol) mixtures was built at temperatures ranging from (273.15 to 323.15) K using the isothermal dissolution equilibrium method [31,32]. The content of ACTE in equilibrium with the liquid phase was determined with the high-performance liquid phase chromatograph (HPLC; Agilent Technologies, USA).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The solid-liquid phase equilibrium of ACET in (acetone + methanol), (acetone + ethanol), (acetone + 1-butanol) and (acetone + isopropanol) mixtures was built at temperatures ranging from (273.15 to 323.15) K using the isothermal dissolution equilibrium method [31,32]. The content of ACTE in equilibrium with the liquid phase was determined with the high-performance liquid phase chromatograph (HPLC; Agilent Technologies, USA).…”
Section: Methodsmentioning
confidence: 99%
“…A condenser was connected to glass vessel to avoid solvent escaping. Before the experiment, the reliability of experimental apparatus was verified by determining the solubility of benzoic acid in toluene [31,32].…”
Section: Apparatusmentioning
confidence: 99%
“…An analytical balance (model: BSA224S) having a standard uncertainty of 0.0001 g and provided by Satorius Scientific Instrument (Beijing) was used to determine the mass of the solute, solvent, and saturated solution. The reliability of apparatus was verified in advance by determining the benzoic acid solubility in toluene [40,41].…”
Section: Materials and Apparatusmentioning
confidence: 99%
“…In this work the solid-liquid equilibrium for ribavirin in binary solvent mixtures of (methanol + water), (n-propanol + water), (acetonitrile + water) and (1,4-dioxane + water) was determined by an isothermal dissolution equilibrium method [40][41][42][43][44][45], and the highperformance liquid phase chromatograph was employed to determine the solubility of ribavirin in equilibrium liquid phase.…”
Section: Solubility Measurementmentioning
confidence: 99%
See 1 more Smart Citation