Source self-attenuation in ionization chamber measurements of 57Co solutions

Abstract: Source self-attenuation for solutions of (57)Co of varying density and carrier concentration was measured in nine re-entrant ionization chambers maintained at NIST. The magnitude of the attenuation must be investigated to determine whether a correction is necessary in the determination of the activity of a source that differs in composition from the source used to calibrate the ionization chamber. At our institute, corrections are currently made in the measurement of (144)Ce, (109)Cd, (67)Ga, (195)Au, (166)Ho,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 3 publications
1
1
0
Order By: Relevance
“…This observation is in coherence with the increase of the source self-attenuation as long as the increase of density of the solution increases (see equation ( 1)). This effect has already been experimentally studied by A Rytz in 1978 for the 241 Am emitting 60 keV γrays [24] and by Cessna et al in 2016 for the 57 Co mainly emitting 122 keV γ-rays in a NIST ionization chamber [25]. Thus, the lack of robustness of the ionization chambers and thus of the SIR for radionuclides that emit only low-energy x-rays or gamma rays is confirmed by the present study.…”
Section: Influence Of the Properties Of The Solutionssupporting
confidence: 85%
“…This observation is in coherence with the increase of the source self-attenuation as long as the increase of density of the solution increases (see equation ( 1)). This effect has already been experimentally studied by A Rytz in 1978 for the 241 Am emitting 60 keV γrays [24] and by Cessna et al in 2016 for the 57 Co mainly emitting 122 keV γ-rays in a NIST ionization chamber [25]. Thus, the lack of robustness of the ionization chambers and thus of the SIR for radionuclides that emit only low-energy x-rays or gamma rays is confirmed by the present study.…”
Section: Influence Of the Properties Of The Solutionssupporting
confidence: 85%
“…Many researchers investigated the effect of SACF to calculate accurate activity concentration of the samples using gamma-ray spectrometry. [8,21,23,29,[30][31][32][33]. The peak count ratio for given energy in a gamma-ray spectrum can easily be used to calculate the intensity of gamma rays at that energy.…”
Section: Introductionmentioning
confidence: 99%